System information
17-Nov-2014 G2T Programmers Guide Rev-A
67
7. Error Code List
The following is a standard list of error codes. Please note that
some codes may not be applicable to all types of equipment or
configurations. See notes at the bottom of the table for
applicability and other information.
The types of errors are divided into four classifications:
1. E = Execution
2. C = Command
3. F = Fault
4. Q = Query
All errors are 1 or 2-digits (except faults which are 3 to 4 digits). The
first two digits are defined in the table below. The last two digits
are application specific.
Error
Type
Description
1
E
Invalid output parameter
2
E
Invalid input parameter
3
E
Invalid command
4
E
Output already connected to different Input
5
E
Blocking input connected already
6
E
Output not connected to anything
8
E
Memory location not used yet
9
E
Bad command argument
10
E
Invalid slot parameter
11
E
Not a valid “GET” property
12
E
Not a valid “SET” property
14
E
Store (*SAV) or Recall (*RCL) out of range
15
E
Set or Get not defined for this system
16
F
Remote missing (Master only). See note 1.
17
F
No top route (Master only). See note 1.
18
F
No bottom route (Master only). See note 1.
19
F
Excessive faults in remote. See note 1.
21
E
Command length error
22
E
No mid-stage available
26
E
Non existing module
27
E
Coil error from relay(s)
28
E
Memory location for “*SAV” temporarily not available.
See note 2.
31
Q
Lost command (new command sent before last
response read)
32
E
Wrong mid
-stage addressed – Partial ganging (parallel).
See note 3.
33
E
Path is not excluded. See note 3.
34
E
List is full, no more exclusions. See note 3.
35
E
Path is excluded. See note 3.