System information
17-Nov-2014 G2T Programmers Guide Rev-A
27
3. STO Commands
The following STO commands executed from the front panel are
currently applicable:
•
STO 213
Press the STO button on the front panel keypad and 213 to
perform a self-test or verify module(s) installation.
•
STO222
Press the STO button on the front panel keypad and 222 to
set the switching system to 488.2 protocol.
•
STO 223
Press the STO button on the front panel keypad and 223 to
set the system to backwards compatibility.
•
STO 224
Press the STO button on the front panel keypad and 224 to
perform a Forceclose.
•
STO 225
Press the STO button on the front panel keypad and 225 to
display system CPU state (dual or single).
•
STO 226
Press the STO button on the front panel keypad and 226 to
suppress monitoring the second power supply.
•
STO 231
In G2T400 (2RU) mainframes only, press the STO button on
the front panel keypad and 231 to deactivate the rear
panel remote control ports and activate the remote
control ports on the front of the CPU. The front panel
display will show “Front Panel”. Enter the command again
to reverse the effect. The front panel display will show
“Rear Panel”.