System information

G2T Programmers Guide Rev-A 17-Nov-2014
20
NOTE: The factory default is Auto-Interlock mode enabled
(On).
To change the setting, slide the toggle to the On or Off positions.
2.12.2.2.2. Power On AutoRestore
The Power On AutoRestore parameter may be enabled (On) or
disabled (Off). When enabled, the unit automatically restores the
last configuration from before the unit was powered OFF (or power
was lost to the unit). When disabled, all cross-points are
automatically cleared on power ON.
NOTE: The factory default is Power On AutoRestore enabled
(On), so that the unit is returned to the last known cross-point
state when powered ON.
To change the setting, slide the toggle to the On or Off positions.
2.12.2.2.3. Auto-Route Mode or Ganged Mode
Depending upon the system requirements, the system may be
enabled in either “AUTO-ROUTE” mode or “GANGED” mode.
The AUTO-ROUTE mode routes the connection command without
the need to address a specific module number. Tri-Stage or
Output End-to-End systems are configured in AUTO-ROUTE mode.
The GANGED mode may or may not require a specific module
number depending on the selection of “virtual poles”. Parallel
systems, such as clock/data switches, may be configured in
GANGED mode.
2.12.2.2.4. Beep On Error
The unit has an internal beeper to indicate an error. This assists the
user during firmware development and alerts the user of
equipment failure. The unit also has a RED front panel LED labeled
ERR1 that illuminates during an error condition.
NOTE: The factory default is Beep On Error enabled (On).
To change the setting, slide the toggle to the On or Off positions.