User manual

27 of 38
5.5 RS-232 Function (RS-232 cable is optional)
Use the tool Hyper Terminal or other tools to control the ProPLAY HD with ASCII command.
NOTE. 1.Baud Rates:
- Firmware Updating: Set up the baud rate to 115200, 8,n,1.
- ASCII Command: The available baud rates is 38400, 8,n,1.
Commands end with a Carriage return (Hex 0D)
Use a Null-Modem cable (Crossover, female-female)
2. The reaction time of ProPLAY HD is around three seconds.
n Keyboard Layout
q: POWER -: VOL - w: SLOW
R: RETURN *: MUTE >: NEXT
!: REPEAT S: SELECT <: PREW
~: SETUP A: Auto Download u: UP
#: TV MODE p: PLAY d: DOWN
%: AutoPlay P: PAUSE/STEP l: LEFT
i: INFO x: STOP r: RIGHT
m: NTSC/PAL f: FFW s: ENTER
$: SEARCH b: REW C: CLEAR
+: VOL +
(XXXXX.XXX): Play The File (xxxxx.xxx is the file name)
NOTE: Must include the round brackets.
[number]:
Action 1: Play the file by index (numbers < upper case letters < lowercase letter).
Action 2: Control the play button to execute the action (the file playlist.ini must be on the CF
card ).
n Pin Assignment
D Sub 9Pin Female D Sub 9Pin Female
Pin 1 Pin 4
Pin 2 Pin 3
Pin 3 Pin 2
Pin 4 Pin 1
Pin 5 Pin 5
Pin 6 Pin 6
Pin 7 Pin 8
Pin 8 Pin 7
Pin 9 Pin 9