System information

Integrating Polycom DMA Systems with Siemens OpenScape
85
6 Configure the following settings on the DMA Signaling Configuration screen:
SIP Settings
» SIP Signaling Check to enable.
» Unencrypted SIP port Choose TCP, 5060.
» TLS port 5061
Next, add an external SIP peer.
To external SIP peer the DMA system:
1 Launch your web browser and enter the IP Address of your DMA System, for example,
http://10.1.1.24 .
2 Click on Continue to this website (not recommended).
3 Type in the User ID (default is admin) and type in the Password (default is admin).
4 Select your Domain (default is LOCAL).
5 Go to Log in > Network > External SIP Peer, as shown next.