System information
Integrating Polycom RMX Systems with Siemens OpenScape
43
2 Set the following system flags:
○ SIP_FREE_VIDEO_RESOURCES NO
This setting is required because the OpenScape Desktop Client escalates from Audio to Video and
is mandatory.
○ ENABLE_SIP_PPC_FOR_ALL_USER_AGENT YES
This setting is required to enable Binary Floor Control Protocol (BFCP), which enables content over
SIP, between the RMX system and the HDX system and is mandatory.
○ ENABLE_FLOW_CONTROL_REINVITE NO
This flag is related to enable BFCP and is mandatory.
○ ENABLE_H239 YES
This setting enables H239 and is mandatory.
○ MULTIPLE_SERVICES YES
This setting enables network separation and is only required if you use network separation.