SPLIT TYPE WALL MOUNTED AIR CONDITIONER USER’S MANUAL CSD-12X/A2214 Read the manual carefully before operation and keep it for reference. This manual is only for reference, please comply with actual appliance you selected. manufacturer hold the authority to redesign or modify its products without notice.
SAFETY PRECAUTIONS WARNING: Following these basic precautions will reduce the risk of fire, electrical shock, injury or death when using your air conditioner. 1. Air conditioner must be connected to proper electrical outlet with the correct electrical supply. And only the specified power can be used. 2. Proper grounding must be ensured to reduce the risk of shock and fire DO NOT CUT OR REMOVE THE GROUNDING PRONG.
USER’S MANUAL CONTENTS 1. SAFETY INSTRUCTIONS Symbol Description…………………………………………………..……….………..….2 Installation Instruction…………………………………………………..…….……….…. 2 Operating Instruction………………………………………………………….……….…..3 Safety Instruction… …………………………………………………………..……….… 6 2. PRODUCT INTRODUCTION Protect Functions…………………………….……………………….. …….………….…7 3. DESCRIPTION OF COMPONENTS View of Unit……………………………………………………………….……..…………8 Display screen…………………………………………………….……….….……..…….9 Indicator light………………………………………………………………….……..
USER’S MANUAL SAFETY INSTRUCTIONS 〖Symbol Description〗 Warning: A symbol indicating operation which may cause personnel casualties or serious damages. Caution: A symbol indicating operation which may cause personnel casualties or property damages. 〖Installation Instruction〗 Warning ) Never install by yourself. Split type air conditioner will work for you for a long period of time if it is correctly installed.
USER’S MANUAL 〖Operating Instruction〗 WARNINGS Following the safety messages is very important. These messages can save you from being injured or killed. Warning symbols alert you to be careful and means danger. Always follow instructions to be safe and reduce chances of injury or death. Warning and danger signs will precede safety messages. Electrical safety Grounding: This room air conditioner must be grounded.
USER’S MANUAL Tips z Install the unit on the north side, as normally that is the shaded side. This will enhance the operation of your unit. z Use correct electric voltage and proper ampere for the unit to run effectively. z Only let a certified electrician do any modifications to your electrical outlet. z Use a dedicated line for the operation of your air conditioner to avoid the possibility of an electrical surge.
USER’S MANUAL 〖Operating Instruction〗 Only single-phase a.c. power can be used. Use the specified power cord; do not change it. Do not put fingers or sticks into the inlet or outlet of air conditioner; the running fan may cause injuries. Do not put anything on the outdoor unit. Do not switch on or off the unit by plugging or pulling off the plug. Keep indoor ventilated, especially when there is operating gas equipment. Do not substitute fuse with lead wire or other materials.(fuse:50T T3.
USER’S MANUAL 〖Safety Instruction〗 Warning: The appliance is not intend for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Don not connect the earth line to gas pipe, water pipe. Improper grounding may cause electric shock.
USER’S MANUAL PRODUCT INTRODUCTION 〖Protect Functions〗 Protect functions can prolong the air conditioner’ s service life and provide more comfortable airflow. Delay-starting protection for the compressor The compressor will restart working at least 3 minutes (5 minutes in heating mode) after being turned off to keep the pressure balance of the cooling system. Remarks: There will be 1 minute for the compressor to work after the unit is electrified for the first time.
USER’S MANUAL DESCRIPTION OF COMPONENTS 〖View of Unit〗 Air inlet Indoor unit Air outlet Power cord Pipe and wires Outdoor unit Air inlet(back) Air outlet Discharge pipe Remarks: The air conditioner is consisting of indoor unit, outdoor unit and remote controller. The design and shape are different for different models. The above figures are only schematic, and they may be slightly different from the actual appliances you selected.
USER’S MANUAL 〖Display screen〗 Receiver:This receiver receives signal from remote controller. “PAUSE” indicator:This indicator lights red when air conditioner is in defrosting or Cooling airflow proof mode. “RUN” indicator:This signal light is on when the unit is is in “RUNNING” status “TIMER” indicator:This signal light is on when the unit is in Timer “AIR REFRESH” indicator:This signal light is on when the unit is running in air refresh mode.
USER’S MANUAL 〖Indicator light〗 ① “PAUSE” indicator This indicator lights red when air conditioner is in defrosting or Cooling airflow proof mode. ② “RUNNING” indicator This indicator lights green when the unit is in “RUNNING” status; air conditioner is in HEAT, COOL, SWEEP, DRY mode. ③“TIMER” indicator (Yellow) This indicator lights yellow when the unit is in TIMER mode.
USER’S MANUAL 〖Remote Controller〗 Inductor sending signals of room temperature to unit every 3 minutes. ON/OFF Button Press this button to start / stop air conditioner. Display Screen Display running status Temp Buttons Press “ ” to decrease temp. Press “ ” to increase temp. ON/OFF Air ventilate button (Not available) Smart Button To realize intelligentized operation. TEMP Fan Sweep button Press the button to adjust the vertical direction of airflow.
USER’S MANUAL 〖Remote Controller Display〗 Operation Mode Selection Display COOL DRY Signal Emission Symbol It appears when control signal is emitted. HEAT Smart Operation Display Press“SMART”button to realize intelligentized operation. Symbol for Energy Saving Except Smart Mode, less symbol means saving more electricity. Fan speed Selection Auto A Medium Display Low High AUH Display The symbol appears when pressing ”AUH” button in HEAT or SMART mode.
USER’S MANUAL OPERATION METHOD 〖Smart Operation〗 Smart Operation ON/OFF Press “SMART” button, the air conditioner will enter intelligentized operation. Cancel Smart Operation TEMP Press MODE button to cancel SMART operation. AIR EXCHANGE Switch Off SMART SWEEP Press this button to stop air conditioner. SPEED 1 2 3 H-SWEEP MODE Remarks: 1.
USER’S MANUAL 〖COOL,DRY and HEAT OPERATION〗 Mode setting For selecting: COOL DRY 1 HEAT Temp setting Press “ ”and “ ” to adjust the temp as needed. 2 ON/OFF Turn on Press“ON/OFF” button to start the air conditioner. 3 Airflow Selection Press “Fan Sweep” button to set airflow in vertical direction. 4 TEMP AIR EXCHANGE SMART SWEEP SPEED Fan speed setting For selecting indoor fan speed: Auto A Low Medium High H-SWEEP MODE Turn off Press“ON/OFF” button again to stop the air conditioner.
USER’S MANUAL 〖Off Timer〗 Press “ Off Timer ”, you can choose 1-8 hours circularly to turn off the air conditioner at the set time. Remarks: 1. When off timer is set, air conditioner will be turned off at the set time. 2. Press “TIMER” to cancel “Off Timer” function and the air conditioner will stop if pressing “ON/OFF” Button. 〖How to Adjust Air Flow〗 Horizontal direction Adjust the horizontal airflow direction by hand. (Fig.
USER’S MANUAL SERVICE AND MAINTENANCE Careful maintenance and overhaul in advance can prolong the air conditioner’ s service life and save electricity charges. Caution: 1. Stop air conditioner by remote controller and pull off the plug before service and maintenance. 2. Do not stand on unstable objects when you clean or service air conditioner, or it may cause personnel injury. 3. Do not touch the metal part of the body when you remove the front panel, or it may cause personnel injury.
USER’S MANUAL 1. Slide the decorated board and move it away as fig.5.2.1 shown; pull the front panel to the outside at a small angel as fig.5.2.2 shown; and then open the front panel as fig.5.2.3 shown. 2. Lift the protruding part which is in the downside of the air filter, then pull it downward, remove the air filter away. 3. Clean it with vacuum cleaner or water. If air filter is very dirt, please clean it with warm soapy water or mild detergent. Then dry it in the shadow. 4.
USER’S MANUAL 〖Recommendations for Energy Saving 〗 Avoid Direct Sunlight Appropriate Temp Setting When it is cooling, please use curtain or It is harmful to health if the room is too cold. blind to obstruct direct sunlight. Avoid Heat Sources Close Doors and Windows When it is cooling, using other heat sources Incoming outdoor air will affect the cooling may affect cooling effect. or heating efficiency.
USER’S MANUAL TROUBLE SHOOTING 〖Air Conditioner is in Error〗 Checking before service. Phenomenon Checking Items 1. Check whether the power is disconnected. Air Conditioner Does 2. Check whether the breaker is switched on or the fuse is burnt. Not Operate At All 3. Check the remote controller batteries. 4. Check whether radio equipment is used within 1m around the unit. 1. Check whether the air inlet or outlet is blocked. Poor Cooling or Heating Performance 2.
USER’S MANUAL NORMAL PHENOMENONS When it is heating or cooling, plastic substance may give out a sound because of the temperature change. If the indoor humidity is too high, water drops may form on the front grill of indoor unit. This is a normal phenomenon. There may be gentle “rustle” sound when the unit starts or stops. It is the normal sound of flowing refrigerant. Walls, carpet, furniture or clothes indoors may disseminate peculiar smell.
USER’S MANUAL JUZ3.867.