Installation manual

901265-01K
For more information, visit www.desatech.com
For more information, visit www.desatech.com
10
LIGHTING
INSTRUCTIONS
OPERATING APPLIANCE
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
GAS SHUTOFF
VALVE OPERATION
Flame Adjustment
Adjust the flame ON/OFF by turning the gas shutoff valve
counterclockwise to open or clockwise to close,
as necessary.
Shutting Off Appliance
Turn gas shutoff valve clockwise to the OFF position.
During the 2-3 hour appliance break-in period, you may detect
an odor from the appliance as the various paints and com-
pounds used in the manufacturing of this log set cure. This is a
normal and temporary situation that is not cause for alarm.
However, you may want to provide extra ventilation to the room
during this time.
To ensure proper curing of the logs:
Ignite a 2" flame and maintain it for 1 hour.
Burn the logs in consecutive 1 hour periods raising the flame
an additional 2" to full flame height for a total of three hours.
CURING
LOGS
1. STOP! Read the safety information, above.
2. Turn the gas shutoff valve to OFF.
3. Wait five (5) minutes to clear out any gas. If you then smell
gas STOP! Follow the safety information above. If you don't
smell gas, go on to the next step.
4. Light a match and lay it on top of the pan material about
2" from the end of the supply side of the pan
5. Slowly turn the gas shutoff valve ON until the burner ig-
nites. If the burner doesn’t ignite within 10 seconds with
the match burning, turn the shutoff valve OFF and repeat
steps 1 through 4 again.
Note:
Operation instructions for GA9150A Remote Ready
Valve/Pilot Kit will be included with the kit.
1. STOP! Read the safety information, column one this page.
2. Make sure equipment shutoff valve is fully open.
3. Press in and turn control knob clockwise to the
OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for
gas around log set and near floor. If you smell gas, STOP!
Refer to the National Fuel Gas Codes, ANSI Z233.1/NFPA
54, Section 5.3, Air for Combustion and Ventilation. If you
don’t smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT
position and press in. Keep control knob pressed in for five
(5) seconds.
Note:
You may be running this log set for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds. This will allow air to
bleed from the gas system.
If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
OPERATING INSTRUCTIONS
FOR GA9050A
Ignitor
Control Knob
Pilot
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
ON
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
ON OFF
On
Off
OFF
OFF
Figure 18 - Ignitor and Control Knob
WARNING: Keep flue open when operating unit.
OPERATING APPLIANCE
For Your Safety Read Before Lighting
Lighting Instructions
Gas Shutoff Valve Operation
Curing Logs