Installation manual
www.desatech.com
901265-01S14
GAS SHUTOFF
VALVE OPERATION
Adjust the ame ON/OFF by turning gas shut-
off valve counterclockwise   to open or 
clockwise   to close, as necessary.
Shutting Off Appliance
Turn  gas  shutoff  valve  clockwise    to 
OFF position.
CURING 
LOGS
During the 2-3 hour appliance break-in period, 
you may detect an odor  from the appliance 
as  various  paints  and  compounds  used  in 
manufacturing of this log set cure. This is a 
normal  and  temporary  situation  that  is  not 
cause for alarm. However, you may want to 
provide extra  ventilation to the  room during 
this time.
To ensure proper curing of the logs:
•  Ignite  a  2"  ame  and  maintain  it  for  1 
hour.
•  Burn logs in consecutive 1 hour periods 
raising the  ame  an additional 2"  to  full 
ame height for a total of three hours.
OPERATING
INSTRUCTIONS
FOR GA9050A-1
Note: Operation instructions for GA9050A-1 
Remote Ready Valve/Pilot Kit will be included 
with the kit.
1.  STOP!  Read  the  safety  information, 
column 1.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Press in and turn control knob clockwise 
 to the OFF position.
4.  Wait ve (5) minutes to clear out any gas. 
Then  smell  for  gas  around  log  set  and 
near oor. If you smell gas, STOP! Refer 
to  the  National  Fuel  Gas  Codes,  ANSI 
Z233.1/NFPA 54, Air for Combustion and 
Ventilation. If you don’t smell gas, go to 
the next step.
5.  Turn  control  knob  counterclockwise 
 to the PILOT position and press 
in. Keep control knob pressed in for ve 
(5) seconds.
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
  
 WARNING: If you do not fol-
  
     
-
-
WHAT TO DO IF YOU SMELL GAS
 
 
 
     
 
LIGHTING 
 INSTRUCTIONS
1.  STOP!  Read  the  safety  information, 
above.
2.  Turn gas shutoff valve to OFF.
3.  Wait ve (5) minutes to clear out any gas. 
If you then smell gas  STOP! Follow the 
safety  information,  above.  If  you  don't 
smell gas, go on to the next step.
4.  Light  a  match  and  lay  it  on  top  of  pan 
material about 2" from end of supply side 
of pan
5.  Slowly  turn  gas  shutoff  valve  ON  until 
burner  ignites.  If  burner  doesn’t  ignite 
within  10  seconds  with  match  burning, 
turn shutoff valve OFF and repeat steps 
1 through 4 again.