Installation manual

www.desatech.com
107331-01H8
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Mantel Shelf
13"
16"
19"
21"
2
1
/2
"
6"
8"
10"
For
CGFB32C
Series
circulating
louvered
models
only
Note:
A
ll vertical measurements
are from top of fireplace
opening to bottom of mantel
shelf. All measurements
are in inches.
Facing material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments.
Mantel Clearances for Built-In
Installation
If placing custom mantel above built-in firebox,
you must meet the minimum allowable clearance
between mantel shelf and top of firebox opening
shown in Figure 7. These are the minimum allow-
able mantel clearances for a safe installation. Use
larger clearances wherever possible to minimize
the heating of objects and materials placed on
the mantel.
CAUTION: Close screens
before operation of vent-free
gas log heater. Do not allow the
heater to touch or extend beyond
the fireplace screen.
If your installation does not meet the minimum
clearances in Figure 7, you must:
raise the mantel to an acceptable height,
OR
remove the mantel.
INSTALLATION
Continued
Figure 7 - Minimum Mantel Clearances
for Built-In Installation
INSTALLING BLOWER ACCESSORY
You may install blower accessory GA3750A with
conventional installation (below) or with built-in
installation (see Built-In Installation of Blower
Accessory). To install blower accessory, see in-
struction sheet included with the kit.
Side
Opening
Support Bracket
Opening
Blower Power
Cord
Figure 8 - Routing Blower Accessory
Power Cord for Conventional Installation
Electrical
Outlet
Blower
Built-In Installation of Blower Accessory
1. Install blower assembly per instruction sheet
included.
2.
Before replacing bottom of firebox, remove screw
holding duplex outlet to the support bracket in
the bottom of firebox. Remove duplex outlet.
3. Clamp electrical cable into firebox through
smallest hole using strain relief provided.
4. Route wires from electrical box through hole
in side of heater and hole in support bracket
(see Figure 9, page 9).
5. Connect wires from the electrical box to
duplex outlet. Match wire colors to those
indicated on duplex outlet. Be sure to connect
ground wire.
Conventional Installation of Blower
Accessory
1. Install blower assembly per instruction sheet
included in blower accessory kit.
2. Before replacing bottom of firebox, route
blower power cord through hole in support
bracket in bottom of firebox and through hole
in side of rebox to grounded, three-prong
120 volt electrical outlet (see Figure 8). Plug
electrical cord into outlet.
3. Replace bottom of firebox.
NOTICE: A certified electrician
must connect electrical wiring to
duplex outlet for built-in instal-
lation. Follow all local codes. In
absence of local codes, follow
the National Electrical Code,
ANSI/NFPA 70 (Latest Edition).