WIRING DIAGRAM
Receiver
Black
On
Off
Remote
Red
Red
White
Thermopile
Gas Control
TPTH TH
TPTH
TP
SPECIFICATIONS
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Max 10.5" W.C., Min* 5" W.C.
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Max 14" W.C., Min* 11" W.C.
* For the purpose of input adjustment