Installation manual

www.desatech.com
111161-01K 23
Manual Mode
1. Press the POWER and LOCK buttons
together to turn on the hand-held remote
control.
2. Press the MANU button to turn on the
replace.
3. Press the POWER and LOCK buttons
together to turn off the replace.
Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons
together to turn on the hand-held remote
control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by
pressing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons
together to turn off the replace
Note: Do not leave the hand-held remote in
the AUTO mode close to the replace. The
radiant heat from the replace will turn off the
replace. Ideally, place the hand-held remote
in the center of the room facing towards the
replace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Check pilot ame pattern and burner ame
patterns often.

Figure 35 shows a correct pilot ame pattern.
Figure 36, shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not properly
heating the thermocouple. When the ther-
mocouple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown
in Figure 36
turn heater off (see To Turn Off Gas to Ap-
pliance, page 21)
see Troubleshooting, page 25
Note: The pilot ame on natural gas units will
have a slight curve, but the ame should be
blue and have no yellow or orange color.
Figure 35 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 36 - Incorrect Pilot Flame Pattern
Natural Gas

Gas
Pilot
Burner
Thermocouple
Natural Gas

Gas
Pilot Burner
OPERATION
Continued
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the replace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1.
If the average room temperature reaches
a range of 82° F (28° C) to 92° F (33° C),
the hand-held remote control will perform a
safety override and shut the replace off. This
feature is not available in the MANU mode.
2. The receiver continuously receives sig-
nals from the hand-held remote to control
the room temperature. If the hand-held
remote is misplaced, obstructed or for any
reason cannot transmit to the receiver, the
receiver will shut off the replace. This will
occur in 8 or more minutes depending
upon location of remote transmitter and
strength of batteries.

This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU
or AUTO mode to prevent inadvertent op-
eration (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
INSPECTING bURNERS