Installation manual

www.desatech.com
111161-01K12
INSTALLATION
Continued


If minimum clearances in Figure 6, page 11,
are not met, you must have a hood. When
using a hood there are still certain minimum
mantel clearances required. Follow minimum
clearances shown in Figure 7, page 11, when
using hood.
  
-

    
     
-


Follow all minimum clearances

NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one

     

 

 
FLOOR CLEARANCES
A. If installing appliance on the oor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14"
to the replace, you must install appliance
at least 5" above the combustible ooring
(see Figure 9).
14"
Min.
Combustible
Material
Noncombustible Material
Hearth
5"
Min.
Combustible
Material
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
-

Note: When used as a vented heater, ap-
pliance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.
If you choose to use your heater as a manu-
ally-controlled model (no remote control
installed), you may use this heater as a vented
product. There are three reasons for operating
your heater in the vented mode.
1. Fireplace does not meet the clearance to
combustibles requirements for vent-free
operation.
2. State or local codes do not permit vent-
free operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you,
you must permanently open chimney ue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
34). This will insure vented operation (see
Figure 10, page 13). The damper clamp will
keep damper open. Installation instructions
are included with clamp accessory.
See chart below for minimum permanent ue
opening you must provide. Attach damper
clamp so the minimum permanent ue open-
ing will be maintained at all times.
 

6' to 15' 39 sq. inches
15' to 30' 29 sq. inches

Diameter Area
5"
6"
7"
8"
20 sq. inches
29 sq. inches
39 sq. inches
51 sq. inches