Product Overview
‘SVH’ Series
Single Zone Ductless Mini-Splits Systems
Heat Pump Models
FEATURES SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1
Power Supply
115V 208/230V 115V 208/230V 208/230V 208/230V
Cooling Capacity (BTUH) 9,000 9,000 12,000 12,000 18,000 24,000
SEER/ EER 15.2/10.0 15.0/10.5 16.0/10.0 15.5/10.2 15.5/11.0 15.0/9.0
HSPF 7.4 7.2 7.8 7.8 8.2 7.4
Cooling Amps 8 3.7 10.4 5.3 7.3 11.8
Dehumidication (Pts/Hr.) 1.0 1.0 1.2 1.2 1.8 2.5
Heating Capacity (BTUH) 9,800 9,800 12,000 12,000 18,000 24,000
Heating Amps 8.60 4.50 5.65 5.40 7.60 11.30
INDOOR UNIT
Air ow (CFM) 265/212/159 265/212/159 318/241/176 318/241/176 424/341/200 565/447/341
Fan Speeds (Cool/Heat/Fan) 3 3
3 3 3 3
Sound Level (dBa) H-M-L
41/35/26 41/36/27 41/36/28 42/36/27 43.5/36/34.5 45/38/32
AIR DIRECTION
Vertical Adjustment Remote Remote Remote Remote Remote Remote
Horizontal (left/right) Manual Manual Manual Manual Manual Manual
Auto Swing Up and Down Standard Standard Standard Standard Standard Standard
INDICATOR LAMPS
Defrost Standard Standard Standard Standard Standard Standard
Temperature Setting Remote Temperature Set Range: 62°F to 86°F
INDOOR UNIT DIMENSIONS
Width (inches)
28-1/8 28-1/8 31-3/4
31-3/4 37-3/4 40-7/8
Height (inches)
11-1/4 11-1/4 11-1/4
11-1/4 11-7/8 12-7/8
Depth (inches)
7-5/8 7-5/8 7-3/4
7-3/4 8-3/8 8-5/8
Net Wt/Shipping Wt (lbs.) 15.9/20.5 15.9/20.5 17.2/22 17.2/22 22.9/29.5 29.3/36.6
OUTDOOR UNIT DIMENSIONS
Width (inches) 30-3/8 30-3/8 30-3/8 30-3/8 31-1/2 33-1/4
Height (inches)
21-7/8 21-7/8 21-7/8
21-7/8 21-7/8 27-5/8
Depth (inches)
11-7/8 11-7/8 11-7/8
11-7/8 13-1/8 14-1/4
Net Wt/Shipping Wt (lbs.)
61.5/66.6 57.1/62.4 65/70.1
60.6/66.4 80.5/87.1 105.2/112.4
ELECTRICAL DATA OUTDOOR UNIT*
Main Power Connection Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit
Min. Circuit Ampacity 15 15 15 15 15 15
Max. Fuse/HACR
Circuit Breaker
15 15 20 15 20 25
Recommended Indoor/
Outdoor Connecting Cable*
14 AWG / 4 conductor
600V THHN unshielded bare copper
LINE SETS O.D. (inch)
Liquid Connection (are) (inch)
1/4 1/4 1/4 1/4 1/4 3/8
Suction Connection (are) (inch)
3/8 3/8 1/2 1/2 1/2 5/8
Maximum Line Set Length
1
82 82 82 82 98 98
Maximum Elevation (outdoor)
2
33 32 33 33 66 66
* Always follow local, state and national
electrical codes.
1
Min. 10 ft. line set recommended.
2
Oil traps should be installed every 16.5 to
23 feet (5-7m) when the outdoor unit is
installed above the indoor unit.
Design, specications and performance