Install Instructions
Installation and Operation Manual - SVH 09/12/18/24 Series
If you will install the unit on the ground or
on a concrete mounting platform, do the
following:
1. Mark the positions for four expansion bolts
based on dimensions in the Unit Mounting
Dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Clean concrete dust away from holes.
4. Place a nut on the end of each expansion bolt.
5. Hammer expansion bolts into the pre-drilled
holes.
6. Remove the nuts from expansion bolts, and
place outdoor unit on bolts.
7. Put washer on each expansion bolt, then
replace the nuts.
8. Using a wrench, tighten each nut until snug.
WARNING
Step 3: Anchor outdoor unit
The outdoor unit can be anchored
to the ground or to a wall-mounted
bracket.
UNIT MOUNTING DIMENSIONS
The following is a list of dierent
outdoor unit sizes and the distance
between their mounting feet.
Prepare the installation base of the
unit according to the dimensions
below.
A
W
B
D
Air inlet
Air outlet
Air inlet
A
W
B
D
Air inlet
Air outlet
Air inlet
Fig. 4.5
Outdoor Unit
Installation
WHEN DRILLING INTO CONCRETE, EYE
PROTECTION IS RECOMMENDED AT ALL
TIMES.
Outdoor Unit Dimensions (mm/in)
W x H x D
Mounting Dimensions
Distance A (mm/in) Distance B (mm/in)
24 845x702x363 (33.25”x27.63”x14.29”)
540 (21.26”)
350 (13.8”)
9/12 770x555x300 (30.3”x21.85”x11.81”)
487 (19.2”) 298 (11.73”)
18 800x554x333 (31.5”x21.8”x13.1”)
514 (20.24”) 340 (13.39”)
22