Submittal Sheet

REV CODE
REVISION
NOM. CFM X 100
2 TON ADD ON COOLING
3 TON ADD ON COOLING
4 TON ADD ON COOLING
5 TON ADD ON COOLING
CABINET WIDTH
A = 14.5” WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
BTUH INPUT
HEATING INPUT X 1000
GAS
G = GAS FURNACE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
DD = DOWNFLOW
AFUE
80 = 80% EFFICENCY
92 = 92% EFFICENCY
95 = 95% EFFICENCY
96 = 96% EFFICENCY
STAGES/MOTOR
G UH 96 T 0 4 5 B 3 M
A =SINGLE STAGE PSC
C =SINGLE STAGE CONSTANT TORQUE
T = TWO STAGE VARIABLE SPEED ECM
MODEL NUMBER GUIDE
Airow Descriptor
Disposable Filters Cleanable Filters
Minimum Area (sq. in.) Minimum Area (sq. in.)
12 576 288
16 768 384
20 960 480
FILTER REQUIREMENT DATA
1. The Airflow Descriptor is the two digits following the "B", "C", or "D" in the model number; e.g. "20" is the Airflow Descriptor.
2. Areas shown for permanent filters are based on filters rated at 600 feet per minute face velocity.
DIMENSIONS (IN.)
Model A B C D
UPFLOW/HORIZONTAL
GUH96T045B3M 17-1/2 16-3/8 16 7-5/8
GUH96T070B3M 17-1/2 16-3/8 16 7-5/8
GUH96T090C3M 21 19-7/8 19-1/2 9-3/8
GUH96T090C5M 21 19-7/8 19-1/2 9-3/8
GUH96T110C5M 21 19-7/8 19-1/2 9-3/8
GUH96T135D5M 24-1/2 23-3/8 23 11-1/8
FRONT VIEW
TOP VIEW
RIGHT SIDE
VIEW
BOTTOM
VIEW