Submittal Sheet

SPECIFICATIONS
Cogurations
• Upow / Horizontal
• Downow
Heat Exchanger Design
Aluminized steel primary heat exchanger with crimped non-welded
construction
• AL 29-4c stainless steel secondary heat exchanger
Cabinet Design
Compact 33" height
Standardized widths for easy coil fit
Unitized construction for cabinet integrity
Heat exchanger compartment is insulated to increase efficiency and
reduce sound levels
Baked on pre painted steel cabinet finish
Air Delivery System
Efficient ECM variable speed blower motor
Motor features "soft start" and "soft stop" for quiet operation
Active and passive dehumidification feature
Easily removable slide-out blower design
Dynamically balanced blower wheel with resilient
motor mounts for smooth and quiet operation
Controls
Two stage gas valve
Integrated ignition and fan control
Control board retains last five (5) fault codes with push button
memory recall, regardless of power interruption
Hot surface ignition system uses silicon nitride ignitor
C o n t r o l f e a t u r e s 1 2 0 v o l t e l e c t r o n i c a i r c l e a n e r a n d h u m i d i f i e r
terminals
Control circuit is fuse protected
Color coded control wiring
Compatible with single or two stage thermostats for heating.
Two stage thermostat is recommended when installed with two
stage cooling unit.
Venting
2-speed induced draft motor with stainless steel shaft, steel ball
bearings, and fan cooled for long life
Certified for direct vent (2-pipe) or non-direct (1-pipe) applications
Installation Features
Left or right gas and electric entry
Zero step horizontal conversion
Removable floor base (upflow/horizontal units) for bottom return air
TWO STAGE VARIABLE
SPEED GAS FURNACE
96%
Warranty
Standard warranty or Extended warranty available with product registration.
See warranty document for details or visit www.marsdelivers.com