Brochure
19
Can be installed for vertical upow or downow, and horizontal left or right airow without
switching any components. ECM blower motor delivers quiet operation with maximum
efciency. Fully insulated cabinet with factory installed A-coil; R-410A TXV and all aluminum
evaporator coil.
WDG Series Air Handlers for Geo Split Systems
BTUH Ratings: cooling at 59°F entering
water temperature; heating at 50°F entering
water temperature.
Electric heater kits available in 240V/208V,
2.9 to 14.4kW. Heater mounts internally in
units; control board activates elements via
internally wired low voltage harness.
Model
Approx. Air Flow
CFM
Coil Dimensions (in.)
Width Depth Height
MWG24TB 600/800 17
1
/2 17
7
/8 20
MWG24TC 600/800 21
1
/2 17
1
/2 20
MWG36TC 825/1175 21 17
1
/2 20
MWG36TD 825/1175 24
1
/2 30
1
/4 32
MWG48TC 1000/1600 21 25
7
/8 28
MWG48TD 1000/1600 24
1
/2 30
1
/4 32
MWG60TD 1050/1700 24
1
/2 30
1
/4 32
Cased coils are ideal for dual
fuel add-on applications.
Fully insulated cabinets
come with dual right and
left hand condensate drain
connections. Fully insulated
cabinet includes corrosion-
proof drain pan, and all
aluminum evaporator coil.
Equipped with TXV. AHRI
certied when matched with
HZS split units.
MWG Series Coils for Geo Split Systems
Coils t a variety of furnace models with widths of 17
1
/2", 21", and 24
1
/2".
Model
Cabinet Size
(in.)
AHRI
Match
Split HP
Capacity
Modulation
Groundwater BTUH
Cooling /EER Heating/COP
WDG24VSA 18
1
/2 x 44 HZS024 Full 27,800/24.9 24,100/4.60
WDG24VSB 22
1
/2 x 55 HZS024 Part 21,700/31.3 18,000/5.00
WDG36VSB 22
1
/2 x 55 HZS036 Full 41,900/25.0 34,300/4.70
WDG36VSC 25
1
/2 x 59 HZS036 Part 30,100/32.3 24,800/5.00
WDG48VSB 22
1
/2 x 55 HZS048 Full 52,700/23.7 46,600/4.60
WDG48VSC 25
1
/2 x 59 HZS048 Part 40,000/29.4 34,600/5.00
WDG60VSC 25
1
/2 x 59 HZS060
Full 63,000/21.9 57,900/4.20
Part 47,600/27.1 43,000/4.60
Efcient, compact two
stage heat pump with
ECM blower motor,
integrated digital
communication controls,
and scroll compressor.
Large lter improves
indoor air quality.
Available in vertical or
horizontal cabinet.
208/230-1-60
BTUH Ratings: Cooling at 59°F entering water temperature; heating at 50°F entering water temperature.
GeoLogix
TM
HEV Series Heat Pump
Model
Capacity
Modulation Specs for Groundwater Installation EER/COP
HEV/HEH
024
Full
Part
BTUH: 26,500 cooling/23,000 heating
BTUH: 20,300 cooling/16,700 heating
21.7/4.1
27.2/4.4
HEV/HEH
030
Full
Part
BTUH: 32,300 cooling/30,000 heating
BTUH: 24,900 cooling/22,000 heating
20.7/4.2
24.8/4.3
HEV/HEH
036
Full
Part
BTUH: 38,200 cooling/35,100 heating
BTUH: 29,000 cooling/24,900 heating
22.3/4.3
29.4/4.6
HEV/HEH
042
Full
Part
BTUH: 46,300 cooling/42,300 heating
BTUH: 35,200 cooling/30,500 heating
21.3/4.1
26.4/4.3
HEV/HEH
048
Full
Part
BTUH: 51,800 cooling/45,000 heating
BTUH: 39,200 cooling/32,600 heating
20.9/4.4
26.8/4.6
HEV/HEH
060
Full
Part
BTUH: 68,000 cooling/55,400 heating
BTUH: 50,400 cooling/39,800 heating
22.7/4.3
28.9/4.5