Brochure

19
Can be installed for vertical upow or downow, and horizontal left or right airow without
switching any components. ECM blower motor delivers quiet operation with maximum
efciency. Fully insulated cabinet with factory installed A-coil; R-410A TXV and all aluminum
evaporator coil.
WDG Series Air Handlers for Geo Split Systems
BTUH Ratings: cooling at 59°F entering
water temperature; heating at 50°F entering
water temperature.
Electric heater kits available in 240V/208V,
2.9 to 14.4kW. Heater mounts internally in
units; control board activates elements via
internally wired low voltage harness.
Model
Approx. Air Flow
CFM
Coil Dimensions (in.)
Width Depth Height
MWG24TB 600/800 17
1
/2 17
7
/8 20
MWG24TC 600/800 21
1
/2 17
1
/2 20
MWG36TC 825/1175 21 17
1
/2 20
MWG36TD 825/1175 24
1
/2 30
1
/4 32
MWG48TC 1000/1600 21 25
7
/8 28
MWG48TD 1000/1600 24
1
/2 30
1
/4 32
MWG60TD 1050/1700 24
1
/2 30
1
/4 32
Cased coils are ideal for dual
fuel add-on applications.
Fully insulated cabinets
come with dual right and
left hand condensate drain
connections. Fully insulated
cabinet includes corrosion-
proof drain pan, and all
aluminum evaporator coil.
Equipped with TXV. AHRI
certied when matched with
HZS split units.
MWG Series Coils for Geo Split Systems
Coils t a variety of furnace models with widths of 17
1
/2", 21", and 24
1
/2".
Model
Cabinet Size
(in.)
AHRI
Match
Split HP
Capacity
Modulation
Groundwater BTUH
Cooling /EER Heating/COP
WDG24VSA 18
1
/2 x 44 HZS024 Full 27,800/24.9 24,100/4.60
WDG24VSB 22
1
/2 x 55 HZS024 Part 21,700/31.3 18,000/5.00
WDG36VSB 22
1
/2 x 55 HZS036 Full 41,900/25.0 34,300/4.70
WDG36VSC 25
1
/2 x 59 HZS036 Part 30,100/32.3 24,800/5.00
WDG48VSB 22
1
/2 x 55 HZS048 Full 52,700/23.7 46,600/4.60
WDG48VSC 25
1
/2 x 59 HZS048 Part 40,000/29.4 34,600/5.00
WDG60VSC 25
1
/2 x 59 HZS060
Full 63,000/21.9 57,900/4.20
Part 47,600/27.1 43,000/4.60
Efcient, compact two
stage heat pump with
ECM blower motor,
integrated digital
communication controls,
and scroll compressor.
Large lter improves
indoor air quality.
Available in vertical or
horizontal cabinet.
208/230-1-60
BTUH Ratings: Cooling at 59°F entering water temperature; heating at 50°F entering water temperature.
GeoLogix
TM
HEV Series Heat Pump
Model
Capacity
Modulation Specs for Groundwater Installation EER/COP
HEV/HEH
024
Full
Part
BTUH: 26,500 cooling/23,000 heating
BTUH: 20,300 cooling/16,700 heating
21.7/4.1
27.2/4.4
HEV/HEH
030
Full
Part
BTUH: 32,300 cooling/30,000 heating
BTUH: 24,900 cooling/22,000 heating
20.7/4.2
24.8/4.3
HEV/HEH
036
Full
Part
BTUH: 38,200 cooling/35,100 heating
BTUH: 29,000 cooling/24,900 heating
22.3/4.3
29.4/4.6
HEV/HEH
042
Full
Part
BTUH: 46,300 cooling/42,300 heating
BTUH: 35,200 cooling/30,500 heating
21.3/4.1
26.4/4.3
HEV/HEH
048
Full
Part
BTUH: 51,800 cooling/45,000 heating
BTUH: 39,200 cooling/32,600 heating
20.9/4.4
26.8/4.6
HEV/HEH
060
Full
Part
BTUH: 68,000 cooling/55,400 heating
BTUH: 50,400 cooling/39,800 heating
22.7/4.3
28.9/4.5