Submittal Sheet

PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
%
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
UPFLOW / HORIZONTAL
GUH80A045A3M 44,000 35,000 80.0% 2 - 3 1/2 120-60-1 15 6.1 40 110
GUH80A070A2M 66,000 54,000 80.0% 1.5 - 2 1/2 120-60-1 15 3.1 40 114
GUH80A070A3M 66,000 54,000 80.0% 2 - 3 1/2 120-60-1 15 6.1 40 119
GUH80A090B3M 88,000 71,000 80.0% 2 - 3 1/2 120-60-1 15 6.1 40 131
GUH80A090B4M 88,000 71,000 80.0% 3 - 4 1/2 120-60-1 15 8.2 40 183
GUH80A110C4M 110,000 89,000 80.0% 3 - 4 1/2 120-60-1 15 8.2 40 151
GUH80A110C5M 110,000 89,000 80.0% 4 - 5 1/2 120-60-1 15 10 40 161
GUH80A135D5M 132,000 107,000 80.0% 4 - 5 1/2 120-60-1 15 10 40 174
DOWNFLOW
GDD80A045A3M 44,000 35,200 80.0% 2 - 3 1/2 120-60-1 15 6.1 40 112
GDD80A070A3M 66,000 52,800 80.0% 2 - 3 1/2 120-60-1 15 6.1 40 121
GDD80A090B4M 88,000 70,400 80.0% 3 - 4 1/2 120-60-1 15 8.2 40 140
GDD80A110C5M 110,000 88,000 80.0% 4 - 5 1/2 120-60-1 15 10 40 163
Note: For vent length and clearances to combustibles, please reference installation instructions.
MODEL NUMBER GUIDE
REV CODE
REVISION
NOM. CFM X 100
2 TON ADD ON COOLING
3 TON ADD ON COOLING
4 TON ADD ON COOLING
5 TON ADD ON COOLING
CABINET WIDTH
A = 14.5” WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5 WIDTH
BTUH INPUT
HEATING INPUT X 1000
GAS
G = GAS FURNACE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
DD = DOWNFLOW
AFUE
80 = 80% EFFICENCY
92 = 92% EFFICENCY
95 = 95% EFFICENCY
STAGES/MOTOR
G UH 80 A 0 4 5 B 3 M
A = SINGLE STAGE PSC
C = SINGLE STAGE CONSTANT TORQUE
T = TWO STAGE VARIABLE SPEED ECM