Install Instructions

Installation Manual - B-VMH18,24UU-1
9
M
N
P
llaw kcab morf 8.11 / mc 03
thgir no 6.32 / mc 06
60 cm / 2
3.6above
tfel no 8.11 / mc 03
norf ni 87 / mc 002 t
Fig. 6.10
Drain Joint Installation
Seal
Drain joint
(A) (B)
Base pan hole of
outdoor unit
Seal
Fig. 6.11
Notes On Drilling Hole In Wall
1. Determine the location of the wall hole based on the
location of the outdoor unit.
2.
3.
NOTE: The minimum distance between the outdoor
unit and walls described in the installation guide does
not apply to airtight rooms. Be sure to keep the unit
unobstructed in at least two of the three directions (M,
N, P) (See Fig. 6.10)
If the drain joint comes with a rubber seal
(see Fig. 6.11 - A ),
do the following:
1. Fit the rubber seal on the end of the drain joint
connect to the outdoor unit.
that will
2. Insert the drain joint into the hole in the base pan of the
unit.
3. Rotate the drain joint 90° until it clicks in place facing the
front of the unit.
4. Connect a drain hose extension (not included) to the drain
joint to redirect water from the unit during heating mode.
If the drain joint doesn’t come with a rubber seal
(see Fig. 6.11 - B ), do the following:
1. Insert the drain joint into the hole in the base pan of the
unit. The drain joint will click in place.
2. Connect a drain hose extension (not included) to the drain
joint to redirect water from the unit during heating mode.
NOTE: Make sure the water drains to a safe location
where it will not cause water damage or a slipping
hazard.
You must drill a hole in the wall for the refrigerant piping,
and the signal cable that will connect the indoor and outdoor
units.
Using a 65-mm (2.5”) core drill, drill a hole in the wall.
NOTE: When drilling the wall hole, make sure
to avoid wires, plumbing, and other sensitive
components.
Place the protective wall cu in the hole. This
protects the edges of the hole and will help seal it
when you nish the installation process.