User Guide
Installation & Operation Manual - VFH-MB 09/12/18/24 Series
35
Did this eliminate
the malfunction?
End
no
no
no
no
no
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
All the indoor units show
communication malfunction
De-energize,check if the connection
wire of indoor and outdoor unit and
the wire of the eletric box is
connected correctly
Connected correctly?
Reconnect according to
the wiring diagram
Connected correctly?
Reconnect according to
the wiring diagram
De-energize, check if the connection wire between
the outdoor mainboard and the filter board
according to the wiring diagram
Is the connection wire broken?
Replace the
connection wire
Check if there is power input
between the neutral wire and live
wire of the outdoor main board
Is there power input?
Replace the filter board of
the outdoor unit
Resume communication?
Replace the outdoor
mainboard
Replace indoor
mainboard
Did this eliminate
the malfunction?
Did this eliminate
the malfunction?
Did this eliminate