EN TECHNICAL MANUAL Audio/video module for Simplebus1 Ultra Art. UT1020 Simplebus1 Ultra remote camera audio module Art. UT1010VC Passion.Technology.Design.
Warning Intended use This Comelit product has been designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial and public buildings. Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Table of contents Warning............................................................................................. 2 Description........................................................................................ 4 UT1020.......................................................................................................4 UT1010VC..................................................................................................4 Installation notes (Art. UT1020).....................................
Description UT1020 Audio/video module for Ultra entrance panel, Simplebus1 system. For use in systems with power supply unit art.1595 and art. 4888C. Wide-angle colour video camera (field of vision: 120° horizontal, 90° vertical) UT1010VC Audio module designed for connection of an analogue remote camera with PAL standard for Ultra entrance panel, Simplebus1 system. For use in systems with power supply unit art. 1595 and art. 4888C.
1. 2. 3. 2. 4. 5. 6. 7. 13. 14. 15. UP 16. 17. 12. 11. 10. 9. 8. UP Art. UT1010VC 1 1. Indicator LEDs 18. 2 13. Terminal block for connection: 4. Speaker volume control RTE programmable RTE (local lock-release input) or DO input (door open indication) GND RTE or DO input reference negative SE door lock reference negative NO NC COM relay contacts V- V+ power supply LL bus line connection 14. Ethernet terminal block, only for use in case of additional modules with LAN 5.
90° 100 cm Installation notes (Art. UT1020) 50 cm 165 cm 130 cm 175 cm 120° he camera must not be installed in front of light sources, or in places where the filmed subject is against the light. In T dim environments, we recommend additional lighting is provided.
Technical characteristics Art. UT1020 GENERAL DATA Type Modular Product height (mm) 90 Product width (mm) Product depth (mm) Product weight (g) Product colour Material Flush mounting Surface mounting 100 35 275 Black RAL9005, Transparent, Aluminium Polycarbonate, Aluminium alloy Yes, with specific accessory Yes, with specific accessory COMPATIBLE SYSTEMS Simplebus 2 audio/video with power supply unit art.
Art. UT1010VC GENERAL DATA Type Product height (mm) 90 Product width (mm) Product depth (mm) Product weight (g) Product colour Material Flush mounting Surface mounting 100 35 275 Black RAL9005, Transparent, Aluminium Polycarbonate, Aluminium alloy Yes, with specific accessory Yes, with specific accessory COMPATIBLE SYSTEMS Simplebus 2 audio/video with power supply unit art.
Installation The entrance panel is available in flush-mounted or surface-mounted variants: C = Flush-mounted module holder with finishing frame Flush-mounted box B = Rain shield 3110/2 Rain shield A = Flush-mounted box 3110/1 UT9181 UT9182 Module holder/ finishing frame Flush-mounted installation composition table UT9161 UT9162 3110/3 UT9183 UT9186 3110/4 UT9189 UT9184 UT9163 UT9188 UT9164 B = Surface-mounted housing with frame Rain shield A = Rain shield UT9191 UT9192 UT9193 UT
Flush-mounted installation Optional 2 130 cm 165 cm 1 Optional 1 2 UP BLACK RED 3 10 4 5
2 2 CLACK! CLACK! 1 1 CLACK! CLACK! 3 6 7 MAX 0,2 mm B MAX 0,2 mm C CLACK! 8 1 A 3 CLACK! The button has a nameplate which can be written on (A); alternatively, an adhesive label can be applied (B). The total thickness of the nameplate + adhesive label must not exceed 0.2 mm. You can visit the website pro.comelitgroup.com to download the PDF to print the entrance panel name cards, using the adhesive pre-cut sheets (C) available in our catalogue (Art. UT9110) 2 + Art.
Installation with side-by-side boxes Before installing the boxes in the wall, fit the spacers.
Wall-mounted installation Optional 3 UP 1 130 cm 165 cm 2 Optional 1 2 UP BLACK RED 3 4 5 13
2 2 CLACK! 1 1 CLACK! CLACK! 3 6 CLACK! 3 CLACK! 7 CLACK! 8 1 A The total thickness of the nameplate + adhesive label must not exceed 0.2 mm. B C The button has a nameplate which can be written on (A); alternatively, an adhesive label can be applied (B). MAX 0,2 mm MAX 0,2 mm You can visit the website pro.comelitgroup.com to download the PDF to print the entrance panel name cards, using the adhesive pre-cut sheets (C) available in our catalogue (Art. UT9110) 2 + Art.
Installation with side-by-side boxes 15
Connections Connections for UT1020, UT1010VC 4888C 1595 - + 120-230 V R T GND SE E NO NC C O M V V L + - L UT1020 UT1010VC Max 20 m. Local door-opener button. Variants Variant for using the outdoor entrance panel relay Variant for using a safety door lock 4888C 1595 - 4888C 1595 + - 12/24V AC/DC + 120-230 V 120-230 V R T GND SE E NO NC C O M V V L + - R T GND SE E L UT1020 UT1010VC 230 V NO NC C O M V V L + - L UT1020 UT1010VC ON 12345678 12V/24V AC-DC 10A MAX “C.NC.
Remote camera connection (Art. UT1010VC only) 4888C 1595 - + UP 120-230 V RED V BLACK S R T GND SE E NO NC C O M V V L + - L UT1010VC V S ~ RED BLACK V S Max 20 m. Local door-opener button.
Module connection Connection of button modules Art. UT9200 4888C 1595 - UP + 120-230 V BLACK R T GND SE E NO NC C O M V V L + - L UT1020 UT1010VC RED UT9200 Max 20 m. Local door-opener button. Connection of Touch-screen module Art. UT9270 4888C 1595 - + 120-230 V R T GND SE E NO NC C O M V V L + - L UT1020 UT1010VC UT9270 Max 20 m. Local door-opener button.
Connection of numeric keypad module Art. UT9279M 4888C 1595 - + 120-230 V R T GND SE E NO NC C O M V V L + - L UT1020 UT1010VC UT9279M Max 20 m. Local door-opener button.
Programming For correct programming, follow the instructions below in order I. Configure button type II. Address button modules III. Program call addresses I Configure button type (single/dual) DIP 6: configuring button type: ON 5678 OFF default Single button (DIP6 ON). 5678 Dual button (DIP6 OFF, default). DIP 6: configuring button type: ON Single button (DIP6 ON). ON 56 123456 OFF 56 default Dual button (DIP6 OFF, default).
Smart programming of consecutive addresses Make sure the button configuration (single/dual) is correct before proceeding with programming (see “Configure button type (single/dual)”) S1 S2 LL 1 Take note of the DIP-switch settings ON 12345678 example: code 1 2 3 Set the address of the apartment you wish to call (for example: 1) using the DIPswitches (see “Addressing table” ) 4 +1 = 2 +1 = 3 = 1 Press the button you want to associate with the call address set using the DIP-switches 5 +1 = 4 +
Programming of specific addresses Make sure the button configuration (single/dual) is correct before proceeding with programming (see “Configure button type (single/dual)”) S1 S2 LL 1 Take note of the DIP-switch settings 12345678 example: code 25 2 3 Set the address of the apartment you wish to call (for example: 25) using the DIPswitches (see “Addressing table” ) 4 example: code 37 = 25 Press the button you want to associate with the call address set using the DIP-switches 5 example: code 70
Special programming via DIP-switch S1 S2 LL 1 Take note of the DIP-switch settings 2 3 1. Set the dip switches in accordance with the function you wish to program (see table). 2. Press the confirm button.
Special programming table CODE DIP SWITCHES ON 195 196 197 198 199 206 207 211 215 216 217 218 219 220 221 222 1,2,7,8 3,7,8 1,3,7,8 2,3,7,8 1,2,3,7,8 2,3,4,7,8 1,2,3,4,7.8 1,2,5,7,8 1,2,3,5,7.8 4,5,7,8 1,4,5,7,8 2,4,5,7,8 1,2,4,5,7.8 3,4,5,7,8 1,3,4,5,7.8 2,3,4,5,7.
238 2,3,4,6,7.8 Self activation: disabled 154 155 2,4,5,8 1,2,4,5,8 239 240 1,2,3,4,6,7,8 5,6,7,8 243 244 1,2,5,6,7.8 3,5,6,7,8 208 5,7,8 209 1,5,7,8 249 250 1,4,5,6,7.8 2,4,5,6,7.8 142 143 2,3,4,8 1,2,3,4,8 158 159 160 2,3,4,5,8 1,2,3,4,5.8 6.
Twilight sensor Camera LED lighting and button backlighting management The twilight sensor is in AUTO mode by default: the camera and button LEDs light up at night and switch off during the day. To change the setting to ON (LEDs always on) or OFF (LEDs always off), proceed as follows: S1 S2 LL 1 Take note of the DIP-switch settings 2 3 Set the desired mode for the camera (A) or button (B) LEDs and press the confirm button OFF 1 2 4 ON AUTO (default) ON ON ON 12345678 12345678 12345678 cod.
Checking twilight sensor operation S1 S2 S1 S2 5 sec 1 2 3 If it is daytime and you want to check AUTO mode operation for the twilight sensor, you can proceed as follows: 1. Enter programming mode 2. Block the twilight sensor for 5 seconds »» If AUTO mode has been set, the camera and button LEDs will come on. 3.
Adjusting the brightness of the button LEDs and the camera light S1 S2 LL 1 Take note of the DIP-switch settings 2 3 Enable brightness control (A) for the camera (code 171) cod. 171 1 ON or 12345678 (B) for the buttons (code 161) Set the desired function (code 171/161) and press the confirm programming button cod.
S1 S2 6 7 Reset the configuration of the DIP-switches When programming is complete, make sure the button configuration is correct (single/dual), see “Configure button type (single/dual)”) Light-me function Thanks to this function, button backlighting is only enabled on the user’s request, by pressing the LIGHT-ME button on the audio/video module; this saves energy and reduces light pollution. Backlighting management for this button depends on the twilight sensor setting.
Replacing the audio/video module with programming restore backup If the audio or audio/video module is replaced, the following instructions must be observed. The procedure should be completed within one hour of removal of the old module. 3 3 1 1 4 2 1 5 2 2 Take note of the DIP-switch settings 1 OLD NEW 2 3 1 1 2 4 1. Enter programming mode by moving S2 DIP-switch upwards 2 ON S1 S2 flashes for the duration of »» the red “system busy” LED the procedure 2.
Configuring via PC All device configurations can be performed via PC and ViP Manager configuration software, available to download free of charge from pro.comelitgroup.com. √√ You will need a USB micro-USB cable.
Addressing table Code Dip switch ON 1 1 31 1,2,3,4,5 61 1,3,4,5,6 91 1,2,4,5,7 121 1,4,5,6,7 151 1,2,3,5,8 181 1,3,5,6,8 211 1,2,5,7,8 2 2 32 6 62 2,3,4,5,6 92 3,4,5,7 122 2,4,5,6,7 152 4,5,8 182 2,3,5,6,8 212 3,5,7,8 3 1.2 33 1.6 63 1,2,3,4,5.6 93 1,3,4,5,7 123 1,2,4,5,6.7 153 1,4,5,8 183 1,2,3,5,6.8 213 1,3,5,7,8 4 3 34 2.6 64 7 94 2,3,4,5,7 124 3,4,5,6,7 154 2,4,5,8 184 4,5,6,8 214 2,3,5,7,8 5 1.3 35 1,2,6 65 1.7 95 1,2,3,4,5.
1st edition 09/2020 code 2G40002537 CERTIFIED MANAGEMENT SYSTEMS w w w.comelitgroup.