4. IF IT IS NOT WORKING:
NO PHONE CONNECTION:
- Checkiftheprogrammingswitchissetto1.
- Checktheconnectionbyconnectingthetelephonedirecttothemainline.
- CheckthepowerontheTrunkterminals(A,B;TRUNK,TRUNK).Thismustbethesameasonthetelephonelineterminals(TEL).
NO CONTACT WITH THE SIMPLEBUS SYSTEM:
- DirectafterprogrammingtheSimplebuscode,theLEDshowsthestatusofthebusline.IftheLEDblinks4times,measurethanthepowerbetweenthebuslineterminals
(L-L).(Thismustbebetween17and30VDC).
- Didyouprogramtherightcode?Ifanydoubt,pleasefollowtheprogrammingprocedurementionedinchapter2.
- Ifthetelephonerings,butyouarenotabletospeak,itcouldbethattheinterface,thereasoncouldbetheprogrammedbusmodeintheinterface.Thiscouldhappenifyou
forgottoprogramtheinterface,whileintheprogrammingprocedurethebustypeautomaticallywillbeadapted.Pleasefollowtheprogrammingprocedureofchapter2.
NO DIVERSION:
- Besurethatthenumberofthediversionhasbeenprogrammedproperly.Iftheinterfaceisconnectedtoatelephoneswitchboard(PABX),normallytheremustbeprogrammed
a"0".Forsomeswitchboardsitcouldbenecessarytoprogramapauseaftertherstnumber,byadding##(waitaftereach#foranacknowledge).
5. SETTINGS OF THE INTERFACE:Inthetablebelowyoundthedefaultsettingsofthetelephoneinterface.
Settable functions Code Default Range Example
A
Communicationtime(call+conversation)with“follow-me”
function
*0nnn 090 000 en 180
*0030(timeto30sec.)
B
Call time from external unit to door-entry phone or local
telephone
*1nnn 030 000 en 180
*1040(timeto40sec.)
C
Conversationtimeafteralocalcallfromexternalunit
*2nnn 090 000 en 180
*2080(timeto80sec.)
D
Delaybefore“follow-me”(calltoremotetelephone)
*3nnn 005 000 en180
*3010(timeto10sec.)
E
ChangeSimplebusaddressmanually*
*9nnn 001 000 en 240
*9130(address130)
F
SettoSimpebus(1)manually(nomixerArt.4888/4888C)
##10 ##10 -
##10(settingtoSB1)
G
Set to Simplebus(2) or SBC manually (mixer Art.
4888/4888C)
##11 ##10 -
##11(settingtoSB2orSBC)
H
Relaytimeontheinterface
#9n 4 0 en 9
#98(timeto8sec.)
I
Theinterfacedoesnotsendackafteracall
*#20 *#21 -
*#20(tobeusedwhenArt.2904ispositioned
beforeaswitchingdevice Art.1224AorArt.
1424,i.e.ontheincomingbuslineconnected
to the LP-LP terminals of the switching
device).
L
Relayoninterfaceswitchedseparately
##71 ##70 -
##71 (the relay is only controlled by the
command#*)
M
Keeplocalphoneringing,while"specialfollowmewithcall
waiting"started(seepointC)
##61 ##60 -
##61(thedoor-entryphoneorlocaltelephone
continuestoring.Press1toanswerfromthe
remotetelephone).
N
Resettofactorysettings
*#0 - -
*#0(tofactorysettings)
* If you use this function, you also must setup the Simplebus mode (dafault SB1). If address 000 is programmed, the interface will activate on all codes.
Ifthesystemisworkingne,butitisdesiredtochangethefactorysettings,pleasefollowtheinstructionsbelow:
Important: An analogue telephone must be connected to the output of the telephone interface.
1Settheprogrammingdipswitchtotheposition"ON".
2Choosebetweenonofthecodesmentionedinthetablefollowedbytherequiredsetting.
Example:settinginternalcalltimeto40sec.(line2)choose:
After programming a confirmation beep will sound.
3Settheprogrammingdipswitchtotheposition"1"toenterintothenormalmode.
6. SPECIFICATIES:
System:  Simplebus1,Simplebus2andSBCaudioandvideo(automaticdetection).
Telephone:  Analoguesystem,transparentforcallidentication
Connections: 12V~ Powerconnection12VACor13,8VDC
A,B TelephonelinePSTN.ConnectiontothetelephoneproviderortowardsPABX
(TRUNK,TRUNK)
Tel Connectionsforananaloguetelephone
NC ConnectionnormallyclosedcontactofrelayinArt.2904
C ConnectioncommoncontactofrelayinArt.2904
NO ConnectionnormallyopencontactofrelayinArt.2904
L,L ConnectionsforSimplebus(1,2orSBC)busline
GND Forlaterexpansionpurpose
Do Forlaterexpansionpurpose
V+ Forlaterexpansionpurpose
Settings: 1.Mic.Potentiometerformicrophonesetting(outsidetoinside)