EN TECHNICAL MANUAL Technical manual for single-family KIT Art. 8461M, 8461MB Passion.Technology. Design.
Warning • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. Do not tamper with the internal elements offering protection against short circuits and overcurrents. • All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made by others for any reason or for the use of non-original accessories or materials.
Table of contents Warning............................................................................................. 2 Package Contents............................................................................ 4 Operating distances......................................................................... 5 Power supply unit Art. 1209............................................................. 6 Description................................................................................................
Package Contents The KIT components are supplied preconfigured for use with the basic version; this manual also includes information for any system configuration and customisation perceived as necessary by the installer.
Operating distances The total number of internal units with the same user code and call repetition devices (additional ringtone Art. 1229A) connected to these internal units cannot exceed 4 (with a maximum of 1 main internal unit and 3 secondary internal units). Connect only one call repetition device for each internal unit. B 1216 6700W 6701W A 6700W 6701W 1214/2C 1209 6700W 6701W 1214/2C A 1209 4893 4893 A MAX B MAX Comelit Art.
Power supply unit Art. 1209 Description 31 Vdc power supply unit for 2-wire KIT, for direct connection to the external unit and internal unit. Equipped with overload and short circuit protection. Input voltage 110-240 VAC. Dimensions: 108x90x62 mm (6 DIN modules). Dopo un cortocircuito,per ripristinare l'apparecchio, interrompere l'alimentazione per circa 1 minuto. To reset the operation after a short circuit,cut off mains voltage for about 1 minute.
External unit Art. 4893 Description Wall-mounted external unit for Quadra series door entry monitor. Die-cast aluminium front panel, wide-angle colour camera and single LED for lighting at night. Capacitive buttons with the option of setting 1 to 4 call buttons via dip switch. Indicator LED for call sent, lock-release activated, audio activated and system busy. Loudspeaker volume adjustment and audio balancing. Bus line power supply. External unit dimensions: 95x195x23 mm.
Installation 1 2 2 OPEN 1 2 3 1 2 4 5 L 6 8 163 cm CAUTION! Tighten properly to avoid leaks 130 cm 1 OM TCE R L 7 optional
You can download the free software (Art. 1235A) from the website www.comelitgroup.com to print the entrance panel name tags, using the adhesive pre-cut sheets available in our catalogue (Art.
External unit settings ff Set the DIP-switches of S1 corresponding to the function that you want to programme as shown in the table below DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 ON ON ON ON ON ON ON ON confirmation tones (call, lock-release, relay, audio enabled): disabled Camera lighting LED: disabled LED lighting of nameholder front panels: OFF OFF OFF OFF confirmation tones (call, lock-release, relay, audio enabled): enabled Camera lighting LED: enabled LED lighting of nam
Call address programming for 2-4 users and additional external unit 1 2 √√ Take note of the DIP-switch settings. example: 3 4 NOTE Fig. 3 - On the DIP-switch, set the code corresponding to the function you want to program as shown in the table on page 11.
Programming a generic call address 1 2 √√ Take note of the DIP-switch settings. example: 3 4 NOTE Fig. 3 - Set the user code on Dip Switches S1 (see table A on page 13).
Riser addresses TAB.
Description of Monitor Art. 6700W and Art. 6701W 1 7 8 2 3 4 9 10 11 5 6 1 2 L L C F P 1 C F P 2 12 1. Brightness control ff To increase the value, turn clockwise 2. Colour intensity adjustment for Art. 6701W Contrast adjustment for B/W monitor Art. 6700W ff To increase the value, turn clockwise 3. 4.3’’ LCD screen (in colour for Art. 6701W, B/W for Art. 6700W) 4. Call volume adjustment (high - medium - low) 5. Soft-touch keys 6. Monitor handset (lift handset to start communication) 7.
Soft-touch keys description ff Press the desired key once to activate the function associated with it Wait for approximately 1 sec. before pressing the same key again. Pressing the same key several times in quick succession will cancel the command. Lock-release key Key 1 Actuator function (programmable) Key 2 Self-ignition function (programmable) Privacy key Keys (programmable) present as standard on all black monitors (for white monitors the KIT with additional buttons Art.
Installation 17,5 cm 16,0 cm optional fixing 1A 1B 1C 2 3 4 CLACK! 1 CLACK! 3 2 1 CLACK! 5 16 2 6 7
Removing / Fitting the terminal 2 1 1 2 3 L L 2 FP C 1 FP C 3 Fitting upgrade KIT Art.
Monitor configuration Standard configuration for soft-touch keys DIP S2 Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) + Art.
Advanced monitor configuration Warning If the default settings (see table on page 18) do not reflect requirements, the keys can be programmed differently by carrying out the steps below. At the end, set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting in the configuration tables on pages 19-23). In this dip switch setting, the keys control the programmed functions; the NON-programmed keys control functions referred to on line 0000 (see table on page 18).
Programming buttons for intercom call Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) + Art.
Direct programming of intercom call Allows direct programming of intercom call via the internal units. √√ Requires 2 operators Step 1: enter programming mode Operator 1 and Operator 2 carry out the following procedures on 2 internal units: 1. Set S2 DIP switches 1-2 -3-4 to the combination 1111 2. Lift the handset 3. Press and hold the privacy and lock-release keys for 3 sec. »» The internal unit emits 1 tone. »» The privacy LED flashes. »» The internal unit enters audio mode.
Programming keys for generic or coded actuator Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) + Art.
Programming buttons for other functions DIP S2 Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) + Art.
Programming range Take note of the S2, S1 setting and restore it when programming is complete Carry out steps 1 to 4 1) 2) 3) 4) S2 DIP Range minimum address 1 2 3 4 5 6 0 0 0 0 1 0 S1 set code, TAB. A on page 13 Range maximum address S2 Enable range S2 DIP OFF Disable range S2 DIP 1 2 3 4 5 6 1 1 1 1 1 0 DIP ON Deleting the range S1 S2 2 sec Monitor ringtone selection 1. Press and hold for 6 sec.
Programming reset Factory settings: • Button functions for the S2 DIP switch 1-2-3-4 combination; • Intercom address absent; • Range function and min./max. addresses absent; • Ringtone reset.
Operation To make a call from an external unit ff To send the call from an external unit, touch the button corresponding to the user you want to contact. If the system is not busy: on the external unit the caller illumination LED will light up, the LED will flash and the confirmation tone will sound. The video image from the external unit will appear automatically on the main internal monitor/s.
OPERATION WITH SWITCHING DEVICE ART. 1404 (DEFAULT) In the configuration of Art. 1404, the MIN and MAX Dip switches define respectively the lowest and highest user codes which can be connected to the riser. For information on setting the desired values, refer to the table on page 13. Separate switching devices for different risers must manage code ranges which are not overlapping.
Installation of door-entry phone Art. 2638 3 4 5 6 7 8 9 115-125 cm 2 140-145 cm 1 Programming of door-entry phone Art. 2638 Set the user code on Dip Switches U2 as indicated in the table on page 13.
Wiring diagrams KIT 8461M-MB: standard single-family system. Switching on/voltage check with system in standby 6700W 6701W 6700W/BM 6701W/BM L C C F 1 F 2 P P L ON ON 12345678 S1 1234 5 67 8 S2 L 110-240V N L2 30 Vdc L2 L1 30 Vdc L1 1209 * Local lock release button.
KIT 8461M-MB: expansion for two-family system 1216 6700W 6701W 6701B L L L L L L C C F 1 F 2 P P 1214/2C 6700W/BM 6701W/BM 6701B/BM + 6710 ON ON 12345678 S1 1234 5 67 8 S2 LM OUT OUT LM L L IN IN 6700W 6701W 6700W/BM 6701W/BM 1214/2C L L OUT OUT L L C C F 1 F 2 P P ON ON 12345678 S1 1234 5 67 8 S2 LM L L LM IN IN L 110-240V N L2 L2 L1 L1 1209 SE SE NC NO C -+ L L R T E C O M D O 4893 8461M-MB Additional monitors Art.
KIT 8461M-MB: expansion for 4-user system 1216 6700W 6701W 6701B L L L L L C C F 1 F 2 P P L 1214/2C 6700W/BM 6701W/BM 6701B/BM + 6710 ON ON 12345678 S1 1234 5 67 8 S2 LM OUT OUT LM L L IN IN 6700W 6701W 6701B L L 6700W/BM 6701W/BM 6701B/BM 1214/2C L L OUT OUT C C F 1 F 2 P P ON ON 12345678 S1 1234 5 67 8 S2 + 6710 LM L L LM IN IN 6700W 6701W 6701B L C C F 1 F 2 P P L 1214/2C 6700W/BM 6701W/BM 6701B/BM + 6710 ON ON 12345678 S1 1234 5 67 8 L L LM OUT OUT LM L L I
KIT 8461M-MB: expansion with second external unit 4893 and switching device Art. 1405 6700W 6701W 6700W/BM 6701W/BM L L C C F 1 F 2 P P ON ON 12345678 S1 1234 5 67 8 S2 1209 L1 L1 L2 L2 L N 110-240V 1405 L L M M SE SE NC NO C -+ L L R T E C O M D O L L L L S S P P SE SE NC NO C -+ L L R T E C O M D O 4893 4893 SLAVE MAIN 8461M-MB # To program the special functions “Main external unit (Porter)” and “Secondary external unit (Porter)”, see page 11.
KIT 8461M-MB: expansion with 3 external units 4893 and switching device Art.
Wiring diagram for system with 2 single-family KITS KIT 8461M-MB and main external unit Art.
KIT 8461M-MB: additional actuator relay Art. 1256 6700W 6701W 6700W/BM 6701W/BM L C C F 1 F 2 P P L ON ON 12345678 S1 1234 5 67 8 S2 JP3 2 JP2 1 2 1 N C JP4 2 1 1200 1256 C N L O L ~~ -+ 230V~ 12V~ 12/24V AC/DC 1214/2C L L OUT OUT LM L L LM IN IN L 110-240V N L2 L2 L1 # For further information see the respective manual. * Local lock release button.
KIT 8461M-MB: additional remote camera module Art. 1409 6700W 6701W 6700W/BM 6701W/BM L C C F 1 F 2 P P L ON ON 12345678 S1 1234 5 67 8 S2 L 110-240V N L2 L2 L1 L1 1209 1409 L L L OUT OUT IN SE SE NC NO C -+ L L IN L ~~ -+ R T E C O M I N A G N D V S V S V S 1 1 2 2 3 3 1200 ON 1234 5 67 8 230V~ 12V~ D O 4893 8461M-MB # To be powered separately. For the setting and operation of Art.1409 see the respective manual. * Local lock release button.
KIT 8461M-MB: additional 2 secondary monitors in cascade connection 6700W 6701W 6700W/BM 6701W/BM CV5 L L 6700W 6701W 6701B C C F 1 F 2 P P 1 2 3 4 5 6 ON ON 12345678 1234 5 67 8 S1 6700W/BM 6701W/BM 6701B/BM S2 P CV5 L 6700W 6701W 6701B C C F 1 F 2 P P L 1 2 3 4 5 6 ON ON 1234 5 67 8 1234 5 67 8 S1 + 6710 S2 S 6700W/BM 6701W/BM 6701B/BM L C C F 1 F 2 P P L 1 2 3 4 5 6 ON ON 1234 5 67 8 S1 + 6710 1234 5 67 8 S2 S 1209 Additional monitors Art.
Connection diagram for system with maximum expansion in branch connection for single call address L CV5 6700W 6701W 6701B 1216 L L 6700W 6701W 6701B C C F 1 F 2 P P L ON 6700W/BM 6701W/BM 6701B/BM ON 12345678 S2 S + 6710 L C C F 1 F 2 P P ON 6700W/BM 6701W/BM 6701B/BM 1234 5 67 8 S1 L ON 1234 5 67 8 1234 5 67 8 S1 S2 S + 6710 1214/2C L L OUT OUT LM L L LM IN IN CV5 6700W 6701W 6700W/BM 6701W/BM L 6700W 6701W 6701B C C F 1 F 2 P P L ON ON 12345678 1234 5 67 8 S1
Connection diagram for branch connection from riser of additional door-entry phones Art. 2628/2638 and Art.
Variant with security door lock and additional power supply 12/24V AC/DC * Local lock release button. * SE SE NC NO C -+ L L R T E C O M D O 4893 SB2/SNPQ Floor door call connection variant * CFP CFP L L If there are a number of door-entry phones or monitor brackets with the same user code, connect the CFP button to one only; all the devices will ring simultaneously.
3rd edition 04/2016 code 2G40001595 w w w.comelitgroup.