Operating instructions
35
Goto Preset – to define the preset position to go to for the Focus Camera if this alarm input is
triggered and the Focus Camera is a PTZ camera. For more details about preset locations, please
refer to Chapter 7 PTZ Control.
Pre-record – to define how long before this alarm input is triggered the Focus Camera shall be
intensively recorded at Pre-record IPS. Press +/- buttons to adjust the value (0-10 seconds,
discrete). Please note that the actual pre-record time may be shorter than the value set if the total
size of the pre-record pictures exceeds the pre-record buffer size of the system.
Post-record – to define how long after this alarm input is triggered the Focus Camera shall be
intensively recorded at Event Record IPS. Press +/- buttons to adjust the value (0 second - 60
minutes, discrete).
Alarm Out
– to define which Alarm Output will be triggered when this alarm input is triggered.
Press +/- buttons to select none (N/A) or one of the Alarm Outputs (1-2).
Buzzer – to activate the internal Buzzer or not when this alarm input is triggered. Press ENTER
or +/- to check/uncheck this item. The default setting is “ˇ
ˇˇ
ˇ” - checked.
Log – to log to event logs or not. Press ENTER or +/- to check/uncheck this item. The default
setting is “ˇ
ˇˇ
ˇ” - checked.
Screen Message – to display the event message on the screen or not. Press ENTER or +/- to
check/uncheck this item. The default setting is “ˇ
ˇˇ
ˇ” - checked.
E-mail
– to send the event e-mail to remote station or not. The e-mail will be sent to the
predefined receivers when the event is triggered. Press ENTER or +/- to check/uncheck this item.
The default setting is “–
––
–” - unchecked.
6.4 SEQ Display Setup
In Setup Menu display, press ▲▼ to change the highlighted option to SEQ Display and then press
ENTER to call up SEQ Display Setup as shown.
The SEQ Display Setup allows the administrator to define the display pages in SEQ Display for
main monitor and call monitor. There are 1 display type – full screen for main monitor and 1 display
type for call monitor.