Operating instructions
Operation Manual – Art. 80153 (Version 1.1.6)
19
5.3 ALARM
Using SELECT button or hold a left mouse button to click icon
“◄” / “►” adjust parameters of each option.
ALARM DURATION
It sets the alarm duration time (in seconds) after alarm is
activated.
Value at “05, 10, 15, 20, 25, 30, CONT, OFF”(in seconds).
Default is “OFF”.
By changing the value in the ALARM DURATION, you can
adjust how long the alarm will last in seconds. The alarm device should be installed.
BUZZER DURATION
It sets the buzzer duration time (in seconds) after alarm is activated.
Value at “05, 10, 15, 20, 25, 30, CONT, OFF” (in seconds). Default is “OFF”. When “buzzer duration” is
“cont”, the buzzer will work continuously.
EVENT REC DURATION
It sets the record time of duration (in seconds) after sensor recording or motion recording or MD & sensor
recording is activated.
Value at “05, 10, 15, 20, 25, 30” (in seconds).
SENSOR
Activate / deactivate or choose the type of sensor. There are
three different modes for sensor setting: N.C
(NORMAL-CLOSE) & N.O (NORMAL-OPEN) & NONE.
Select “None” to deactivate sensor recording or if there was
no sensor installed in DVR system.
Chose the type of sensor (N.O or N.C) installed in DVR.
MOTION DETECTION
CHANNEL
Select the channel (1,2,3,4) for recording mode by internal
motion.
SENSITIVITY
It adjusts the sensitivity of the built-in motion sensor on the
DVR system while recording. The higher the number, the
higher the sensitivity is. Value at “1, 2, 3, 4, Off”. The
maximum sensitivity level is 4.