Specifications

Station Dimensions–continued
Scout 900MX
Base Unit Handset
Footprint (inches) 7.30 X 5.12 8.15 X 2.19 X 1.85 with belt clip
Weight (ounces) 16 oz less AC adapter 8.5 oz with battery and belt clip
Conferencing
Maximum Combinations
at Any One Time
J0408 and J0816 J1632
1 five-way plus 1 three-way plus 2
SOHVA
4 five-way plus 1 three-way plus 1
SOHVA
2 four-way plus 2 SOHVA 6 four-way plus 2 three-way
1 four-way plus 3 three-way 3 four-way plus 9 three-way
5 three-way plus 1 SOHVA 16 three-way
SMDA Storage Capacity
J0408 J0816 J1632
800 1600 1600
Station Cable Requirements
Type 2-wire (1-pair) twisted, non-shielded cable
Maximum Length 1000 feet with 24 gauge wire, 2000 feet with 22 gauge wire
Switching Principle Digital, time division multiplexing (TDM). Provides non-blocking switching with stored
program control
Operating Environment
Temperature 32-122 degrees F (0-50 degrees C)
Humidity 90 percent relative, non-condensing
Power Requirements
J0408 J0816 J1632
JM408 and
JM008
Voltage 90-129 VAC Single phase all models
Current 0.6A 2.0 A 2.1A Not Applicable
Power 70W 135W 150W Not Applicable
Volt/Amps 80VA 190VA 200VA Not Applicable
Terminations
Station Standard 50-pin male connectors for connection to external distribution field
Line Standard 6-conductor mini-jack (USOC 14C)
IMI66–132 DSU II Digital Telephone System
1–22 Introducing The DSU II Digital Telephone System