Specifications

3.6.7 Line To Line Port Re-Assignment
Description: You can reassign the programming attributes for a line that the installer has connected to
a particular line port to a different line port with this programming action. This feature
allows you to automatically exchange all software attributes for one line with those
assigned to another at a different line port without physically re-locating the lines or
reprogramming any of the attributes.
To Program: 1. Dial 41. “ASSIGN LOGICAL/PHYS ”
2. Select currently assigned line port number. “PHYS LATCH XX”
—Line port 1–14 = Dial 0114 or Press A1A14.
—Line port 15, 16 = Dial 15, 16 or press B1, B2.
—Line port 17–24 = Dial 17– 24 or press HOLD then press A1A8.
3. Dial new line port number (0124 = line 1–24). “LOGICAL LINE XX”
4.
Dial
# to make assignment.
5. Repeat steps 2–4 for another assignment
—OR—
dial for configuration mode.
To change setting, repeat procedure and make different selection or make same port
selections in both steps 2 and 3 to match logical to physical assignment.
DSU II Digital Telephone System IMI66–132
Programming The DSU II System 3 – 41