Specifications
3.6.7 Line To Line Port Re-Assignment
Description: You can reassign the programming attributes for a line that the installer has connected to
a particular line port to a different line port with this programming action. This feature
allows you to automatically exchange all software attributes for one line with those
assigned to another at a different line port without physically re-locating the lines or
reprogramming any of the attributes.
To Program: 1. Dial 41. “ASSIGN LOGICAL/PHYS ”
2. Select currently assigned line port number. “PHYS LATCH XX”
—Line port 1–14 = Dial 01–14 or Press A1–A14.
—Line port 15, 16 = Dial 15, 16 or press B1, B2.
—Line port 17–24 = Dial 17– 24 or press HOLD then press A1–A8.
3. Dial new line port number (01–24 = line 1–24). “LOGICAL LINE XX”
4.
Dial
# to make assignment.
5. Repeat steps 2–4 for another assignment
—OR—
dial ✳ for configuration mode.
To change setting, repeat procedure and make different selection or make same port
selections in both steps 2 and 3 to match logical to physical assignment.
DSU II Digital Telephone System IMI66–132
Programming The DSU II System 3 – 41