Specifications
Line and Station Boards and Special Components 
GCA39-825 Rev 2, Issue 4/02  Page 8  Printed in the USA 
Digital E1 Board 
Part Number: FXE1 (Mexico/Europe) (32 Channel Digital E1 Line Board) 
•  A synchronization card is required for E1 operation and for E1 PRI applications. Only 1 sync 
card is needed. (Please look under Auxiliary Equipment in this section for more information.) 
•  An E1 Interface allows up to 32 channels of transmission over a single 4-wire cable. Two of 
the 32 channels are designated “D” channels or “signaling” channels. 
•  Thirty of the E1 channels can be allocated for R2MFC protocol (DID, DOD, 2-way lines), 
R2DTMF protocol, or digital E & M. Line signaling and tone signaling are supported. 
•  E1 supports ANI, CLID, answer and disconnect supervision, and pulse metering. 
•  A customer service unit (CSU) is built into the E1 option board to terminate the E1 channels. 
This eliminates the need to install a CSU external to the system. 
•  Since each board slot in the FX system supports 32 time slots, each E1 board only needs 1 
board slot for full 32 channel operation. 
NOTE: PRI is not currently supported on public networks in Mexico (private networks only). 