Press [
chg
chgchg
chg] (change) to change this value. Each time the [chg
chgchg
chg] button is pressed the value changes from
Y/N. (“Y,” yes indicates that this CO line will be answered by the automated attendant. “N,” no indicates that
it will not.)
Press [
next
nextnext
next]. The next database item (Service) and the current setting displays.
Press [chg
chgchg
chg] (change) to select the appropriate operation mode for automated attendant for this CO line.
(Available options are: ALWAYS, NEVER, DAY, and EVE.)
Press [
next
nextnext
next]. The system prompts for the next CO line to be programmed automated attendant answering.
You may continue programming other CO lines for automated attendant use or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«. The program title page displays.
Press any key at the program title page to enter the Main Menu.
Select PC-DBA from the Main Menu. The PC-DBA menu is then shown.
Select Programming from the PC-DBA menu.
Use
¢£¤¥ to highlight “Call Handling” and then press «.
The cursor is now positioned on the database item - “Call Handling - Category 1.”
Use
¢£¤¥ to highlight Automated Attendant then press «. The cursor is now positioned on the
database item “AAT - Category 1.”
Press « to select this Category or move the cursor to the appropriate data Category for changes to be
made.
Press « to select the specific data item to be changed. The following data items have fixed values that
are scrolled each time the
« button is pressed:
Category 1: No Answer Time, Drop No Dial, XFR Mode
Category 2: Auto Attendant Line, Service
All other Automated Attendant database items require input from the keyboard. When the
« button is
pressed, the data item value is removed and is ready for the new value to be entered. When the necessary
(and valid) data is input, press
«.
Continue programming all those database items where changes are required.
When you have completed all changes, press
° (escape) to exit System Reminder programming. You will
be prompted to confirm exit request; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave System Reminder unchanged.
Press Y” to save changes.
You will then be prompted “File Exists, Override?”
Press N” to abort changes and leave System Reminder unchanged.
Press Y” to save changes.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this