Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 4-23
┌───────────────────────────────── DX80 PC-DBA ────────────────────────────────┐
[Cnt] KSU Revision : K16UM0.F19 Date: 01/02/14
Time: 20:53:22
Status - MDM BOARD :
BUILT-IN MODEM : IDLE
└─────────────────────────────────── R16UM0.F21 ───────────────────────────────┘
┌────────────────────┐
408 BOARD
OPEN
OPEN
APM4 BOARD
COM4 BOARD
└────────────────────┘
┌───────────────────────────────── DX80 PC-DBA ────────────────────────────────┐
[Cnt] KSU Revision : K16UM0.F19 Date: 01/02/14
Time: 20:54:21
Status - 408 BOARD :
TRK POS DIR# STATUS
1/01/1 740 IDLE
1/01/2 741 FAIL
1/01/3 742 FAIL
1/01/4 743 FAIL
EXT POS DIR# TYPE STATUS
1/01/1 101 EXEC. DISPLAY IDLE
1/01/2 102 NO CONNECTION OPEN
1/01/3 103 NO CONNECTION OPEN
1/01/4 104 NO CONNECTION OPEN
1/01/5 105 NO CONNECTION OPEN
1/01/6 106 NO CONNECTION OPEN
1/01/7 107 NO CONNECTION OPEN
1/01/8 108 NO CONNECTION OPEN
└─────────────────────────────────── R16UM0.F21 ───────────────────────────────┘
SW/HW Revision
SW/HW Revision can be invoked to view the current version of software installed in the DX-80. The
Hardware Revision (HW Revision) is a label only field that allows the user of PC-DBA to record the revision
of hardware installed at the site. This information is stored in the Database Save operation of PC-DBA.
Idle = Ready for a call
Busy = Port in use
Status can be:
Idle = equipped and ready
Fail = equipped but errors present.
(CO – no loop current. Ext. lost data
communications)
Open = no hardware recognized
Busy = in use