Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 4-19
┌───────────────────────────────── DX80 PC-DBA ────────────────────────────────┐
[Cnt] KSU Revision : K16UM0.F19 Date: 01/02/14
Time: 20:45:23
Diagnostics - Cabinet 1
BOARD TYPE
BOARD 1 408 BOARD
BOARD 2 OPEN
BOARD 3 OPEN
BOARD 4 APM4
BOARD 5 COM4
└─────────────────────────────────── R16UM0.F21 ───────────────────────────────┘
F1-Help F2-U-Save F3-RCV F4-SND F5-Cnt F6-Disc F7-Prn F8-Init F9-Mdm F10-RS232C
┌───────────────────────────────── DX80 PC-DBA ────────────────────────────────┐
[Cnt] KSU Revision : K16UM0.F19 Date: 01/02/14
Time: 20:45:58
Diagnostics - 408 BOARD :
COL POS DIR# LOOP DISC
1/01/1 740 PASSED PASSED
1/01/2 741 BUSY IN
1/01/3 742 BUSY OUT
1/01/4 743 FAILED FAILED
EXT POS DIR# TYPE RESULT
1/01/1 101 EXEC. DISPLAY PASSED
1/01/2 102 EXEC. DISPLAY FAILED
1/01/3 103 NO CONNECTION OPEN
1/01/4 104 EXEC. DISPLAY OPEN
1/01/5 105 NO CONNECTION OPEN
1/01/6 106 NO CONNECTION OPEN
1/01/7 107 NO CONNECTION OPEN
1/01/8 108 NO CONNECTION OPEN
└─────────────────────────────────── R16UM0.F21 ───────────────────────────────┘
Note:
Cabinet 1 selected.
Move the cursor to any
board and press
« to
get details of that board.
CO Lines:
Ports
1/01/1~1/01/4
Directory
numbers
740~743
Extensions
Ports
1/01/1~1/01/8
Directory
numbers
101~108
Passed = Loop
Current
detected.
Busy
Failed = No
Loo
p
Current
Passed = Loop OK
In = Incoming call
Out = Outgoing call
Failed = Loop Fail
Digital Executive Telephone
No Connection = no device
attached.
Passed = operation OK.
Failed = data communications
error to device.
Open = either no connection ever
registered or previous registered
device is no longer connected.
408 Board Selected