Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-263
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code !+* and then enter the DB Admin password
“
++++++++.” (Note: This eight-character password can be changed.)
• Press [
show
showshow
show]. The DB Item Select screen displays.
Program the extension for the appropriate mode
• Input 01-101~156-08 for Warning Tone (101~156 is the extension to program.)
• Input 01-101~156-09 for Drop Call Out (101~156 is the extension to program.)
• Input 01-101~156-10 for Drop Call In (101~156 is the extension to program.)
• Press [
chg
chgchg
chg] until the appropriate value (Y/N) displays.
• Press [
back
backback
back] or [next
nextnext
next] to select the previous/next DB Item or press the Volume button (up or down) to
return to the DB Item Select screen or exit programming.
Program Warning Time
• Input 03-09-01 for Warning Time Outgoing
• Input 03-09-02 for Warning Time Incoming
• Press [
chg
chgchg
chg] until the appropriate time displays
• Press
the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press
«.
Program extensions for the appropriate Call Limiter
• Use ¢£¤¥ to highlight “Extension.” Then press «.
• Use
¢£¤¥ to highlight “Category 2.” Then press «.
• Use
¢£¤¥ and ³´ to highlight “Warning Tone” or “Drop Call Out” or “Drop Call In” for the
extension to be changed.
• Press
« until the appropriate value displays.
• Continue programming other extensions as required.
• When all changes are complete press the
° (escape) key to exit this database programming screen. You
will see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.