Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-249
Operation – Cancel
While recording a conversation, enter the code !67. The recorder will return to idle and the
conversation up to the time the code was entered (second time) will be recorded in this extensions voice
mailbox. The display will return to the connected condition.
Conditions
a) You may program a Flexible Feature button for this feature code.
b) If you use a Flexible Feature Button for this feature…
• During recorder set-up, the associated lamp for that button will light steady red.
• When recording begins, the lamp will light steady green.
c) Outgoing call recording begins after the Call Duration Timer has expired.
d) Placing a call on hold constitutes completing a call and ends the recording function.
Default Setting
Extension – Record Allow = N (Range is Y/N.)
Programming Abstract
• Program the extension(s) that should be allowed to record calls for Record Allow.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are interactive LCD button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code !+* and then enter the DB Admin password
“
########.” (Note: This password can be changed.)
• Press [
show
showshow
show]. The DB Item Select screen displays.
• Input 01-101~156-20 to program Record Allow for the selected extension (101~156).
• Press [save
savesave
save]. The display will show the current setting for Record Allow for this extension.
• Press [chg
chgchg
chg] until the appropriate value displays.
• Press the
Volume button (up or down) to return the index entry to program another extension 01-101~156-
20 or...
• Exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«. The program title page displays.
• Press any key at the program title page to enter the Main Menu.
• Select PC-DBA from the Main Menu. The PC-DBA menu is then shown.
• Select Programming from the PC-DBA menu.
• Use
¢£¤¥ to highlight “Extension” and then press «.
• Use ¢£¤¥ to highlight “Category 3” and then press «.
• Use
¢£¤¥ and ³´ to highlight Record Allow for the extension number.
• Press « to change the value of the database item (Y/N).
• Continue making changes as required.
• When all changes are made press
° (escape) to exit this programming. You will be prompted to confirm
exit request; press “Y” for yes.