Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-247
Program analog extensions as port type “V.A.”:
• Use
¢£¤¥ to highlight “Extension.” Then press «.
• Use ¢£¤¥ to highlight “Category 2.” Then press «.
• Use
¢£¤¥ and ³´ to highlight “Port Type” for the analog extension to program.
• Press « until the appropriate Port Type (V.A.) displays.
• Continue programming port type for other analog extensions as required.
• When all changes are made press the
° (escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• Press
° (escape) again to return to the Database Programming menu.
Program the Voice Announcer UCD Group:
• Use
¢£¤¥ to highlight “Extension Application.” Then press «.
• Use
¢£¤¥ to highlight “Uniform Call Distribution.” Then press «.
• Input the UCD Group number to be used as the V.A. Group, then press «. This advances to the selected
UCD Group with the cursor positioned on the “Attribute” database item.
• Use ¢£¤¥ to highlight “Members.” Then press «. This advances to this UCD Group Members
database screen.
• Use ¢£¤¥ to highlight the Member to be changed. Then press «.
• Input the extension directory number of the analog extension to be programmed as a member of this UCD
Group. Then press
«.
• Continue making programming changes as required.
• When all changes are made press the ° (escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• Press
° (escape) again to return to the Database Programming menu.
• Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.