Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-231
Select Programming from the PC-DBA menu. Then press
«.
Program Digit Interval(s) and assign Extension/CO Line COS to Digit Intervals:
Use
¢£¤¥ to highlight “Restriction” and then press «.
Use
¢£¤¥ to highlight “Toll Restriction” and then press «.
Use ¢£¤¥ and ³´ to highlight the “FROM” or “TO” column of the Digit Interval.
Press
«.
Input the digit(s) to be monitored. (E.g., to restrict long distance and operator calls, input “2” in the From
column and input “#” in the To column. Thereby eliminating “0” and “1” as possible first dialed digits.)
Use ¢£¤¥ and ³´ to highlight the “Extension” or “CO Line” COS under the service mode “Day” or
“Eve” for the Interval.
Press
« to selectY” or “N” for this COS/Mode/Interval.
When all changes are made press the
° (escape) key to exit this database programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Program Extensions for the COS to follow:
Use
¢£¤¥ to highlight “Extension” and then press «.
Use
¢£¤¥ to highlight “Category 1” and then press «.
Use ¢£¤¥ and ³´ to highlight the COS Day or Eve of the extension for which changes are to be
made.
Press
« until the appropriate COS assignment displays.
Continue making other programming changes as required.
When all changes are made press the
° (escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Program CO Lines for the COS to follow:
Use ¢£¤¥ to highlight “CO Line” and then press «.
Use
¢£¤¥ to highlight “Category 2” and then press «.