Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-230
Program Digit Interval(s) and assign Extension/CO Line COS to Digit Intervals:
Input 05-01-1~3-001~100 (where 1~3 is the Tenant Group and 001~100 is the Interval to program). Then
press [
save
savesave
save]. This advances to the “FROM” column of the tenant group and interval selected.
Press [chg
chgchg
chg] to change the start of this interval range (beginning FROM…).
Input the new starting digit sequence, then press [save
savesave
save].
Press [
next
nextnext
next] to advance to the “TO” column of the tenant group and interval selected.
Press [
chg
chgchg
chg] to change the end of this interval range (up …TO).
Input the new ending digit sequence, then press [save
savesave
save].
Press [next
nextnext
next] to advance to Extension or CO Line COS as required for change.
Press [show
showshow
show]. The DAY Allowed parameter displays for the Extension or CO Line COS.
Press [
next
nextnext
next] to advance to the EVE Allowed COS for the Extension or CO Line COS.
Or…
Press [
show
showshow
show] to program COS allowed settings for this Digit Interval. COS 0 displays.
Press [next
nextnext
next] and [back
backback
back] until the appropriate COS to change displays.
Press [chg
chgchg
chg] until the appropriate setting (Y/N) displays.
Press
the Hold button to return to the previous menu level.
Or…
Press the Volume button (up or down) to return to the DB Item Select screen.
Program Extensions for the COS to follow:
Input 01-101~156-05~06 (where 101~156 is the Extension and 05 is DAY Class Of Service and 06 is EVE
Class Of Service.)
Press [
chg
chgchg
chg] until the appropriate COS displays for the selected service mode.
Press
the Hold button to return to the previous menu level.
Or…
Press
the Volume button (up or down) to return to the DB Item Select screen.
Program CO Lines for the COS to follow:
Input 02-740~755-04~05 (where 740~755 is the CO Line and 04 is DAY Class Of Service and 05 is EVE
Class Of Service.)
Press [
chg
chgchg
chg] until the appropriate COS displays for the selected service mode.
Press
the Hold button to return to the previous menu level or press the Volume button to return to the DB
Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.