Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-224
Related Programming
System Application - Hour Mode, Time Switching
System Resource – Hour Mode
System Resource – Time settings
Conditions
System Time and Date must be set in Database Administration for proper display at digital Executive
Speakerphones and all other time-sensitive feature operations.
Default Settings
Hour Mode set at “12” (Range is 12/24)
System Time – Year “99” (Range is 0-99)
System Time – Month “JAN” (Range is JAN~DEC)
System Time – Day “1” (Range is 1-31)
System Time – Weekday “FRI” (Range is SUN~SAT)
System Time – Hour “00” (Range is 0-23)
System Time – Minute “00” (Range is 0-59)
Programming Abstract
Use Hour Mode to set the display format (12-hour or 24-hour format).
Use the System Time programming to set the system clock to the correct time and date.
Press ALT+T from any PC-DBA programming screen to view and change current settings.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays. (All database programming items are indexed for fast
access. Note: Press the volume up or down bar to return to the DB Item Select screen at any time.)
Input 08-03, then press [save]. This advances to the Hour Mode programming screen.
Press [chg
chgchg
chg] to change to select 12/24 Hour Mode.
Input 08-14, then press [
save
savesave
save]. This advances to the System Time programming screen.
Press [
show
showshow
show], the Year database item displays.
Press [
chg
chgchg
chg] to change the year for the system clock.
Or…
Press [
next
nextnext
next] to advance to the next system clock item that requires changes.
Press [
chg
chgchg
chg] and input data as required.
Follow this convention for each of the database items for the system clock.
Press
the Hold button to exit System Time programming and return to the previous menu level.
Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory, then press Enter.
Press any key at the program title page (as requested) to enter the Main Menu.