Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-223
If you press “Y” (yes), you will then be prompted “File Exists, Override?”
Ø Press N” to abort changes and leave all data unchanged.
Ø Press Y” (yes) to continue with the save operation.
Press ESC (escape) again to return to the Database Programming menu.
To program call logging conditions (Outgoing/Incoming/Account Code):
Use the cursor positioning arrows to highlight “Call Handling” and then press Enter.
Use the cursor arrows to highlight “Category 2” and then press Enter.
Use the cursor arrows to highlight the database item “SMDR Call Output – Outgoing/Incoming/Account
Code” as required.
Press Enter. Each time that enter is pressed the value of this database item is updated.
Continue to make other changes to the Call Output settings as required.
When all changes are made press the ESC (escape) key to exit this database-programming screen.
When you will see the “Exit This Feature?” prompt, press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Ø Press N” to abort changes and leave all data unchanged.
Ø Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?”
Ø Press N” to abort changes and leave all data unchanged.
Ø Press Y” (yes) to continue with the save operation.
Press ESC (escape) again to return to the Database Programming menu.
To program the (CIL) Call Information Log serial port baud rate (CIL X_RATE):
Use the cursor positioning arrows to highlight “System Resource” and then press Enter.
Use the cursor arrows to highlight “Modem & Serial Port” and then press Enter.
Use the cursor arrows to highlight the database item “CIL X_Rate.”
Press Enter. Each time that enter is pressed the value of this database item is updated.
When all changes are made press the ESC (escape) key to exit this database-programming screen.
You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Ø Press N” to abort changes and leave all data unchanged.
Ø Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?”
Ø Press N” to abort changes and leave all data unchanged.
Ø Press Y” (yes) to continue with the save operation.
Press ESC (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: changes made via PC-DBA are NOT updated to the DX-80 system memory until a SEND function has
been performed. Please refer to the Programming Guide section of this manual to learn more about this
procedure.
System Time and Date
The DX-80 system provides a built-in time clock to track System Time for reference in certain features such as
System Night Service Mode Change, SMDR, Alarm Clock – System, Extension, and Time and Date display at
Executive Speakerphones.
This clock is battery protected from power failure. System Time can be changed at any Digital Speakerphone using
the attendant password.
Related Features
Attendant Administration SMDR
Automatic CO Line Ringing Modes Alarm Clock – System, Extension