Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-213
Press [
show
showshow
show]. The DB Item Select screen displays.
Input 03-14, then press [save
savesave
save]. This advances to the SLT Hook Flash programming screen.
Press [show
showshow
show]. This advances to the Start screen.
Press [
chg
chgchg
chg] to change the Start range setting. (This timer indicates the minimum time that an analog/SLT
must flash the hook-switch to be considered a valid flash-hook request. A hook-flash that is shorter than this
timer is considered a mistake; no action is taken.)
Press [
next
nextnext
next]. This advances to the End screen.
Press [chg
chgchg
chg] to change the End range setting. (This timer indicates the Maximum time that an analog/SLT
must flash the hook-switch to be considered a valid flash-hook request. A hook-flash that is longer than this
timer is considered an On-Hook {hang up} request.)
Continue making other programming changes or exit the programming mode.
Press
the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Use
¢£¤¥ to highlight “Call Handling” and then press «.
Use ¢£¤¥ to highlight “Category 2” and then press «.
Use
¢£¤¥ to highlight the database item “SLT Hook Flash – Start or End” as required.
Press « until the appropriate value displays.
Continue making other programming changes as required.
When all changes are made press the
° (escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a SEND function
has been performed. Please refer to the Programming section of this manual to learn more about this