Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-191
• All Call Paging - you can access all paging zones (internal and external).
Paging is one-way only. The Page Allow/Deny setting does not interfere with an extension’s ability to make a page or
to establish a “Meet Me” page.
Related Features
Do Not Disturb External Paging
Meet Me Page Flexible Feature Button Programming
Related Programming
Extension - Paging Group, Paging Allow
System Resource - External Pager
System Application - Ext Page Group, External Pager (see Flexible Numbering Plan).
Operation
1. To make a page announcement the page code must be known. At default the page access codes are as
follows:
• 400 = Tenant All Call
• 401~408 = Page Groups (zones) 1~8
• 777 = External Pager
2. Lift the handset (it is recommended that all page announcements be made using the handset to reduce
potential audio feedback and oscillation {squeal}).
3. Dial the page group/zone directory number.
4. If the selected Page path is not being used, a short page alert tone is heard and the connection is made.
PAGE TENANT X
PAGE GROUP 401
PAGE EXTERNAL
5. Make your page announcement and hang up to end the announcement.
Default Settings
Extension – Paging Group = 1 for all extensions. (Range is 1~8.)
Extension – Paging Allow = Y for all extensions. (Range is Y/N.)
System Resource – External Pager – Tenant Group = 1. (Range is 1~3.)
System Resource – External Pager – Paging Group 1 = Y. (Range is Y/N.)
System Application – Ext Page Group assigns codes 400~408.
System Application – Ext Pager assigns code 777.
Conditions
a) The display will show PAGE FAILURE if a page fails. This is due to that page group/zone being busy.
b) Any of the paging codes may be stored on a programmable feature button.
c) The External Pager port can be programmed to operate with any Page Group via System Resource –
External Pager programming.
Programming Abstract
• Program extensions into paging groups (see Extension Paging Groups).
• Program extensions for the ability to initiate a page announcement.
• Program the External Pager to be associated with the appropriate Tenant Group.
• Program the External Pager to be associated with the Page Groups as required.
• Program directory number access codes (see Flexible Numbering Plan).