Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-185
Default Settings
Extension – Monitor Class is set to “5” for all extensions.
Programming Abstract
Change the Monitor Class for all those extensions that should have the ability to monitor other extensions.
LEGAL NOTICE:
This feature may violate privacy laws if used in a manner that is inconsistent with requirements of these
laws. Manufacturer assumes no responsibility with regard to the use of this feature. It is provided for the
virtue of ethical use only. YOU are responsible for using this feature appropriately considering all applicable
laws.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Input 01-101~156-07, then press [save
savesave
save]. This advances to the Monitor Class programming screen for the
extension selected.
Press [
chg
chgchg
chg] until the appropriate Monitor Class for this extension displays.
Press
the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Use
¢£¤¥ to highlight “Extension” and then press «.
Use
¢£¤¥ to highlight “Category 1” and then press «. The first (of 5) Extension – Category 1
screen displays.
Use ¢£¤¥ and ³´ to highlight the database item “Monitor Class” for the Extension to be changed.
Press
« until the appropriate Monitor Class displays for the selected extension.
Continue making other programming changes as required.
When all changes are made press the
° (escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.