Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-183
Programming Abstract
• Change the modem directory number to the appropriate number.
• Change the modem operating baud rate if the application requires this change.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code
!+* and then enter the DB Admin password
“
++++++++.” (Note: This eight-character password can be changed.)
• Press [
show
showshow
show]. The DB Item Select screen displays.
• Input 04-15. Then press [save
savesave
save]. This advances to the Built-in Modem programming screen.
• Press [show
showshow
show]. This advances to the Built-in Modem – Directory Number programming screen.
• To change the modem directory number, press [chg
chgchg
chg].
• Input the new directory number that is to be assigned to the modem resource. (The directory number
must be from those designated for Extension Directory Numbers.)
• Press [save].
• Press [next
nextnext
next]. This advances to the Built-in Modem – Baud Rate programming screen.
• Press [chg
chgchg
chg] until the appropriate baud rate displays.
• Press
the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press
«.
• Use ¢£¤¥ to highlight “System Resources” and then press «.
• Use
¢£¤¥ to highlight “Modem & Serial Port” and then press «.
• Use ¢£¤¥ to highlight the database item “Built-in Modem – DIR. No.” if the number is to be changed.
• Press
«.
• Input the new directory number and then press enter to temporarily store this data.
• Use
¢£¤¥ to highlight the database item “Built-in Modem – Baud Rate” to change the operating
speed of the modem.
• Press «. Each time that enter is pressed the value of this database item is updated.
• Continue making other programming changes as required.
• When all changes are made press the
° (escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
Press “N” to abort changes and leave all data unchanged.
Press “Y” to save changes.