Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-157
Operation
While connected to a CO Line, press ! and then press the Hold button.
Conditions
a) When you place a CO line call on Exclusive Hold, the green lamp for that line at your telephone will flash
fast and the red lamp will light steady at other extensions for that CO line.
b) A CO line call will be placed on System Hold after the Exclusive Hold time expires. You will hear a tone
alerting you that the timer has expired and the hold condition for that CO line changes to System Hold. The
green lamp at your telephone will flash slowly and the red lamp at other extensions will begin to flash slowly.
c) Exclusive Hold is used only for CO line calls.
d) The Exclusive Hold duration is programmable from 1-8 minutes in the Database Programming.
Default Settings
Call Handling – Hold Reminder is set at “60” seconds.
(Range is: 0-90 seconds, “0” disables the reminder Function.)
Call Handling – Exclusive Hold Time is set at “3” minutes.
(Range is 0-8 minutes. “0” disables Exclusive Hold Recall.)
Programming Abstract
Program the Hold Reminder Time. (See Hold Reminder.)
Program the Exclusive Hold Time.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Input 03-08, then press [save
savesave
save]. This advances to EX_HOLD TIME programming.
Press [chg
chgchg
chg] until the appropriate Exclusive Hold Time displays.
Press
the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Use
¢£¤¥ to highlight “Call Handling.” Then press «.
Use
¢£¤¥ to highlight “Category 1.” Then press «.
Use ¢£¤¥ to highlight “Ex_Hold Time.”
Press
« until the appropriate Exclusive Hold Time displays.
Continue making other programming changes as required.