Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-135
Default Settings
Extension – FTR BTN Disable is set to “N.” (Range is: Y/N.)
Programming Abstract
Program the extension(s) for Feature Button Disable if they are to be restricted from using any system
feature codes.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!:* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Input 01-101~156-16, then press [show
showshow
show].
Press [
chg
chgchg
chg] until the appropriate value displays for the selected extension (101~156).
Press
the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Use
¢£¤¥ to highlight “Extension.” Then press «.
Use ¢£¤¥ to highlight “Category 3.” Then press «.
Use
¢£¤¥ to highlight the database item “FTR. BTN Disable” for the extension to be changed.
Press
« until the appropriate value displays.
When you have completed all changes, press the
° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.