Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-107
Or…
• Press [
next
nextnext
next] to advance to the next Extension COS for programming.
• Follow this convention for each of the Extension Classes of Service using [next
nextnext
next] and [chg
chgchg
chg] operations as
required. Continue pressing the [
next
nextnext
next] button through all Extension Classes of Service until the next
database item displays or press the Hold button to exit Extension Class of Service and exit to the previous
menu.
• Press [
next
nextnext
next] to advance to CO Line specific DISA programming. The CO Line input screen displays SHOW
CO LN.
• Input the CO Line directory number (740~755).
• Press [show
showshow
show]. This advances to the DISA CO LINE (Y/N) screen.
• Press [chg
chgchg
chg] to change this data item value.
• Press [next
nextnext
next] to advance to DISA DAY COS.
• Press [chg
chgchg
chg] until the appropriate value displays. (This data item will determine which extension COS
model to follow for DISA calls made into the system while the system is in DAY mode.)
• Press [
next
nextnext
next] to advance to DISA EVE COS.
• Press [chg
chgchg
chg] until the appropriate value displays. (This data item will determine which extension COS
model to follow for DISA calls made into the system while the system is in Evening mode.)
• Press [
next
nextnext
next] to advance to SERVICE mode.
• Press [chg
chgchg
chg] until the appropriate value displays. (This data item will determine when the DISA feature
will be active for the selected CO Line. NEVER/DAY/EVE/ALWAYS.)
• Press [
next
nextnext
next] to advance to TALK TIME.
• Press [chg
chgchg
chg] until the appropriate value for this data item displays. (The Talk Time will determine the
duration of outgoing CO Line calls made via the DISA feature on this CO Line.)
• Press [
next
nextnext
next]. This advances to the input CO Line directory number screen so that another CO line may be
programmed for DISA if necessary.
• Input the CO Line directory number to program for DISA operation and then press [
show
showshow
show] and set the
necessary data item values as above.
Or…
• Press
the Hold button to exit DISA programming and return to the previous menu level.
• Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press
«.
• Use ¢£¤¥ to highlight “Call Handling.” Then press «.
• Use
¢£¤¥ to highlight “DISA.” Then press «.