Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-107
Or…
Press [
next
nextnext
next] to advance to the next Extension COS for programming.
Follow this convention for each of the Extension Classes of Service using [next
nextnext
next] and [chg
chgchg
chg] operations as
required. Continue pressing the [
next
nextnext
next] button through all Extension Classes of Service until the next
database item displays or press the Hold button to exit Extension Class of Service and exit to the previous
menu.
Press [
next
nextnext
next] to advance to CO Line specific DISA programming. The CO Line input screen displays SHOW
CO LN.
Input the CO Line directory number (740~755).
Press [show
showshow
show]. This advances to the DISA CO LINE (Y/N) screen.
Press [chg
chgchg
chg] to change this data item value.
Press [next
nextnext
next] to advance to DISA DAY COS.
Press [chg
chgchg
chg] until the appropriate value displays. (This data item will determine which extension COS
model to follow for DISA calls made into the system while the system is in DAY mode.)
Press [
next
nextnext
next] to advance to DISA EVE COS.
Press [chg
chgchg
chg] until the appropriate value displays. (This data item will determine which extension COS
model to follow for DISA calls made into the system while the system is in Evening mode.)
Press [
next
nextnext
next] to advance to SERVICE mode.
Press [chg
chgchg
chg] until the appropriate value displays. (This data item will determine when the DISA feature
will be active for the selected CO Line. NEVER/DAY/EVE/ALWAYS.)
Press [
next
nextnext
next] to advance to TALK TIME.
Press [chg
chgchg
chg] until the appropriate value for this data item displays. (The Talk Time will determine the
duration of outgoing CO Line calls made via the DISA feature on this CO Line.)
Press [
next
nextnext
next]. This advances to the input CO Line directory number screen so that another CO line may be
programmed for DISA if necessary.
Input the CO Line directory number to program for DISA operation and then press [
show
showshow
show] and set the
necessary data item values as above.
Or…
Press
the Hold button to exit DISA programming and return to the previous menu level.
Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Use ¢£¤¥ to highlight “Call Handling.” Then press «.
Use
¢£¤¥ to highlight “DISA.” Then press «.