Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-93
h) The Unsupervised Conference feature code
!77 may be programmed on any available
programmable feature button.
i) Only the Controller of an Unsupervised Conference may rejoin an Unsupervised Conference.
j) Conference can only be established at a Digital Speakerphone.
Default Settings
Call Handling – CO Line Conference = 3 CO Lines. (Range is None/2/3.)
Call Handling – Unsupervised Talk Time = 0 (unlimited). (Range is 0-120 in 10-minute increments.)
Call Handling – Conference Tone = Y. (Range is Y/N.)
CO Line – Call Abandon = Y. (Range is Y/N.)
Programming Abstract
• Program the maximum CO Lines that may be in a conference (none, 2 or 3).
• Program the time allowed for Unsupervised Conferences (CO Line-to-CO Line).
• Program the Conference Tone for Yes or No operation.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code
!+* and then enter the DB Admin password
“++++++++.” (Note: This eight-character password can be changed.)
• Press [
show
showshow
show]. The DB Item Select screen displays.
Program the maximum number of CO Lines that may be in a conference. (03-01):
• Input 03-01.
• Press [chg
chgchg
chg] until the appropriate value displays (NO/2LNS/3LNS).
• Continue making other programming changes or exit the programming mode.
Program the Unsupervised Conference Time. (03-38):
• At DB Item Select screen input 03-38
• Press [
chg
chgchg
chg] until the Unsupervised Conference Time displays.
• Continue making other programming changes or exit the programming mode.
Program the Conference Tone Operation. (03-23):
• At DB Item Select screen Input 03-23. Then press [
save
savesave
save].
• Press [chg
chgchg
chg] until the appropriate Conference Tone operation displays (Y/N).
• Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press
«.