Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-90
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Use
¢£¤¥ to highlight “Call Handling.” Then press «.
Program the Meet Me Conference Time:
Use ¢£¤¥ to highlight “Category 2.” Then press «. The CO Line – Category 2 screen displays.
Use ¢£¤¥ to highlight the database item Meet Me Conference Talk Time.
Press «. Each time that enter is pressed the value of this database item is updated.
When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
The main Call Handling screen is again visible.
Program the Conference Tone Operation:
Use
¢£¤¥ to highlight “Category 3.” Then press «.
Use
¢£¤¥ to highlight “Conference Tone.”
Press « until the appropriate value displays. (Y/N)
When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Conference, Supervised/Unsupervised !77
The system can accommodate eight (8), 4 member (party) conferences, simultaneously. Conference combinations
may consist of 3 CO lines maximum and any number of extensions to a maximum of 4 parties (members). One
inside key telephone station is the controller of the conference and constitutes one conference member. Before a
conference can be established with a maximum of 4 members, a 3-member conference must first be established.