Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-90
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press
«.
• Use
¢£¤¥ to highlight “Call Handling.” Then press «.
Program the Meet Me Conference Time:
• Use ¢£¤¥ to highlight “Category 2.” Then press «. The CO Line – Category 2 screen displays.
• Use ¢£¤¥ to highlight the database item Meet Me Conference Talk Time.
• Press «. Each time that enter is pressed the value of this database item is updated.
• When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• The main Call Handling screen is again visible.
Program the Conference Tone Operation:
• Use
¢£¤¥ to highlight “Category 3.” Then press «.
• Use
¢£¤¥ to highlight “Conference Tone.”
• Press « until the appropriate value displays. (Y/N)
• When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• Press
° (escape) again to return to the Database Programming menu.
• Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Conference, Supervised/Unsupervised !77
The system can accommodate eight (8), 4 member (party) conferences, simultaneously. Conference combinations
may consist of 3 CO lines maximum and any number of extensions to a maximum of 4 parties (members). One
inside key telephone station is the controller of the conference and constitutes one conference member. Before a
conference can be established with a maximum of 4 members, a 3-member conference must first be established.