Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-89
Conditions
a) It is highly recommended that the all CO Lines be set at the factory default for Call Abandon (“Y”) to optimize
Meet Me Conference functionality.
b) When Call Abandon is set to “N” for any CO Line, you must set the Meet Me Conference Talk Time to some
value other than 0. This is the only facility that will allow the CO Line to be disconnected if Call Abandon is
No.
c) Up to four simultaneous connections may join any one conference.
d) Up to eight simultaneous conferences may be established at any one time.
Default Settings
Call Handling – Meet Me Conference Talk Time is set at 0 (unlimited).
(Range is: 0-120 minutes, in 10-minute increments.)
Call Handling – Conference Tone is set to “Y” (yes). (Range is: Y/N.)
Call Handling – CO Line Conference = 3 Lines. (Range is None/2/3.)
Programming Abstract
See “System Application – Meet Me Conference” for Directory Number programming
See “CO Line Loop Supervision” for CO Line – Call Abandon programming
See “CO Line Loop Supervision” for Call Handling – Talk Abandon Time
Program Call Handling – CO Line Conference for none/2/3 lines.
Program Call Handling – Meet Me Conference Talk Time to limit conference time for CO Lines involved in
conference calls. (Required when Call Abandon is “N” for any CO Line.)
Program the Call Handling – Conference Tone for Yes/No operation.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Program the Meet Me Conference Time. (03-37):
Input 03-37. Then press [
save
savesave
save].
Press [chg
chgchg
chg] until the Meet Me Conference Time displays.
Continue making other programming changes or exit the programming mode.
Program the Conference Tone Operation. (03-23):
Press
the Volume button (up or down) to return to the DB Item Select screen.
Input 03-23. Then press [save
savesave
save].
Press [chg
chgchg
chg] until the appropriate Conference Tone operation displays (Y/N).
Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.