Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-71
Program CO Lines for Call Abandon. (02-ccc-09, where “ccc” = the CO Line Directory number [740-755]):
Input 02-ccc-09 to program “ccc” CO Line – Call Abandon.
Press [
save
savesave
save]. This advances to the selected CO Line Call Abandon setting for CO Line “ccc.”
Press [chg
chgchg
chg] until the appropriate value (Y/N) displays for this CO Line.
Press
the Volume button (up or down) to return to the DB Item Select screen and input another CO Line.
Or…
Press the
Hold button to select another CO Line to be programmed.
Input the CO Line number then press [show
showshow
show].
Press [next
nextnext
next] to advance through database items until the Call Abandon database item displays.
When finished programming CO Line Call Abandon, press
the Volume button (up or down) to return to the
DB Item Select screen.
Or…
Use [
back
backback
back] or [next
nextnext
next] to skip to the appropriate database item.
Program Call Abandon Timers as required, to match CO operation. (03-41 and 03-42):
At the DB Item Select screen input 03-41 for Talk Abandon (Call Abandon during conversation “talk” mode.)
Or…
03-42 for Hold Abandon (Call Abandon during on hold mode.)
Press [
chg
chgchg
chg].
Input the value for this database item. (Accepted entries are 50-1000, in increments of 50 milliseconds.)
Press [save
savesave
save].
To select the previous or next database item, press [back
backback
back] or [next
nextnext
next].
When finished programming Call Abandon database items, press
the Volume button (up or down) to
return to the DB Item Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Program CO Lines for Call Abandon:
Use ¢£¤¥ to highlight “CO Line.” Then press «.
Use ¢£¤¥ to highlight “Category 1.” Then press «. (Notice the display header “CO Line Category
1 : [1/2].” The “[1/2],” indicates that this is the first of two pages for this database programming. Page 1
shows the programmable database items for CO Line ports 1-8 (CO Lines 740-747).)
Use the
³ and ´ buttons on the PC keyboard to select the screen of Category 1 that show the CO
Line(s) to be programmed.